  • This study proposes a composite reinforcement in which a riprap layer (D50 = 2.5 cm, 15 cm thick) bonded with a castor-oil-derived biopolymer adhesive is embedded in a biopolymer-treated layer, and evaluates it in a 180-min overtopping test on a full-scale levee (height 3.0 m, crest width 4.0 m, landside slope 1V:2H) under overtopping depths increased from 0.05 to 0.31 m.

Abstract

Overtopping is the leading cause of earthen levee failure, and reinforcement that keeps a levee stable during overtopping is needed. This study proposes a composite reinforcement in which a riprap layer (D50 = 2.5 cm, 15 cm thick) bonded with a castor-oil-derived biopolymer adhesive is embedded in a biopolymer-treated layer, and evaluates it in a 180-min overtopping test on a full-scale levee (height 3.0 m, crest width 4.0 m, landside slope 1V:2H) under overtopping depths increased from 0.05 to 0.31 m. Unlike previous studies in which biopolymer-treated soil was exposed directly to the flow, the biopolymer is used here as a binder for riprap, and the hydraulic load and the response of the reinforcement are analysed on a common time axis. STIV-based surface velocities on 20 lines each on the crest and slope were used to derive the unit discharge, slope flow depth, mean boundary shear stress and the momentum-flux index hV2. The mean slope surface velocity increased from 1.42 to 3.47 m/s (maximum 4.05 m/s), with a 26% increase between 100 and 110 min. The mean boundary shear stress on the slope peaked at 430 Pa at 140 min (387 Pa when the unit discharge was estimated by the broad-crested weir equation). The composite layer remained functionally intact for 180 min, with fewer than 10 surface stones dislodged and no exposure of the treated layer or the embankment. The experimentally established lower-bound resistance of the composite layer (at least 430 Pa) exceeds the literature-based critical shear stresses of conventional linings up to fully vegetated turf reinforcement mats (383 Pa); these literature values are indicative thresholds and were not obtained under identical test conditions. A bounding analysis indicates that bonding increased the resistance of the 2.5-cm stones by roughly one order of magnitude (about 35 times) relative to unbonded stones of the same size.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Full-Scale Experimental Evaluation of Biopolymer–Riprap Composite Reinforcement for Enhancing Levee Overtopping Resistance — Science Skim