Symmetry

A Double-Inertial-Embedded Two-Step Mann-Based ELM with CNN Feature Extraction for Alzheimer’s Disease Classification from MRI Images

Watcharaporn Cholamjiak, Phatcharaphon Phuangsuwan, Nithi Baiya, Pasa Sukson, Mohammad Farid

Key points

From the paper's conclusion
  • These findings demonstrate the potential of DIETM-based ELM optimization across different CNN feature extractors for multiclass MRI classification.

Abstract

This study introduces a Double-Inertial-Embedded Two-Step Mann (DIETM) algorithm for approximating a common fixed point of two quasi-nonexpansive mappings in a real Hilbert space. The proposed scheme incorporates two inertial terms into a two-step Mann framework, and its weak convergence is established under suitable assumptions. Numerical experiments in function spaces demonstrate its convergence behavior and computational efficiency compared with classical and inertial iterative methods. To investigate its practical applicability, DIETM is employed to optimize the output weights of an Extreme Learning Machine (ELM) within a hybrid CNN–ELM framework for MRI-based dementia classification. Brain MRI images from the OASIS Alzheimer’s Detection dataset were classified into four dataset-defined categories: Non-Demented, Very Mild Dementia, Mild Dementia, and Moderate Dementia. Following duplicate control and group-aware stratified partitioning, the images were divided into training, validation, and held-out test sets, with brightness augmentation applied only to the training set. Pretrained VGG16 and DenseNet121 networks were employed as fixed-feature extractors and integrated with the proposed DIETM-ELM optimization framework. The proposed approaches were evaluated against end-to-end CNN models, conventional machine learning classifiers, and alternative ELM-based methods. On the held-out test set (N=614), VGG16 + DIETM-ELM achieved an accuracy of 87.13%, balanced accuracy of 89.03%, and macro-F1 score of 89.01%, representing the highest observed performance among the evaluated VGG16-based models. DenseNet121 + DIETM-ELM further improved classification performance, achieving an accuracy of 89.41%, balanced accuracy of 90.97%, and macro-F1 score of 90.84%, although DenseNet121 + SVM attained a slightly higher accuracy of 90.88%. These findings demonstrate the potential of DIETM-based ELM optimization across different CNN feature extractors for multiclass MRI classification. However, the single-dataset evaluation, lack of verified subject-level independence, and absence of external validation limit conclusions regarding its generalizability and clinical applicability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Double-Inertial-Embedded Two-Step Mann-Based ELM with CNN Feature Extraction for Alzheimer’s Disease Classification from MRI Images — Science Skim