A Hybrid of ResNext101_32x8d and Swin Transformer Networks with XAI for Alzheimer’s Disease Detection
Saeed Mohsen, Amr Yousef, M. Abdel-Aziz
Higher Institute of Engineering · University of Business and Technology
Key points
From the paper's conclusion- This paper presents a hybrid model comprising two networks, ResNext101_32x8d and Swin Transformer to differentiate four categories of Alzheimer’s disease: no dementia, very mild dementia, mild dementia, and moderate dementia.
Abstract
Medical images obtained from advanced imaging devices play a crucial role in supporting disease diagnosis and detection. Nevertheless, acquiring such images is often costly and storage-intensive, and it is time-consuming to diagnose individuals. The use of artificial intelligence (AI)-based automated diagnostic systems provides potential solutions to address the limitations of cost and diagnostic time. In particular, deep learning and explainable AI (XAI) techniques provide a reliable and robust approach to classifying medical images. This paper presents a hybrid model comprising two networks, ResNext101_32x8d and Swin Transformer to differentiate four categories of Alzheimer’s disease: no dementia, very mild dementia, mild dementia, and moderate dementia. The combination of the two networks is applied to imbalanced data, trained on 5120 MRI images, validated on 768 images, and tested on 512 other images. Grad-CAM and LIME techniques with a saliency map are employed to interpret the predictions of the model, providing transparent and clinically interpretable decision support. The proposed combination is realized through a TensorFlow framework, incorporating hyperparameter optimization and various data augmentation methods. The performance evaluation of the proposed model is conducted through several metrics, including the error matrix, precision recall (PR), receiver operating characteristic (ROC), accuracy, and loss curves. Experimental results reveal that the hybrid of ResNext101_32x8d and Swin Transformer achieved a testing accuracy of 98.83% with a corresponding loss rate of 0.1019. Furthermore, for the combination “ResNext101_32x8d + Swin Transformer”, the precision, F1-score, and recall were 99.39%, 99.15%, and 98.91%, respectively, while the area under the ROC curve (AUC) was 1.00, “100%”. The combination of proposed networks with XAI techniques establishes a unique contribution to advance medical AI systems and assist radiologists during Alzheimer’s disease screening of patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficient deep learning models for early Alzheimer’s disease diagnosisScientific Reports · 2026
- A Hybrid Architecture of CNN–Swin-T Integrated with Attention Mechanism and Explainable AI for Alzheimer’s Disease ClassificationComputers · 2026
- Hybrid deep learning framework for magnetic resonance imaging-based classification of Alzheimer’s diseaseBrain Network Disorders · 2025
- NeuroEarlyAI: An Explainable Deep Learning Framework with EarlyDetectNet for Alzheimer’s Disease Detection and Classification using MRI ScansInternational Journal of Engineering Trends and Technology · 2026
- A Hybrid Explainable AI Framework (HXAI) for Accurate and Interpretable Diagnosis of Alzheimer’s DiseaseDiagnostics · 2025
- Lightweight Deep Learning Models with Explainable AI for Early Alzheimer’s Detection from Standard MRI ScansDiagnostics · 2025