A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances
Fatih Evran
Key points
From the paper's conclusion- The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.
Abstract
This study presents an adaptive RST polynomial control framework for nonideal DC–DC buck converters under line and load disturbances, explicitly accounting for pulse-width modulation (PWM) update delay. RST refers to a polynomial control structure comprising the R, S, and T polynomials. Conventional fixed-gain controllers are typically designed around a nominal operating point and may therefore lead to degraded voltage regulation, larger transient deviations, increased current stress, and reduced disturbance-rejection capability when converter dynamics vary due to load changes, input-voltage disturbances, parasitic losses, and digital implementation delays. Fixed-parameter model-based polynomial controllers may also fail to preserve the desired closed-loop dynamics when the effective converter parameters vary with the operating condition. To address these limitations, a nonideal averaged model is used to obtain an affine discrete-time input–output representation, and the effective PWM update delay is incorporated into the RST pole-placement design. The plant is identified online using a bias-augmented autoregressive with exogenous input (ARX) model with forgetting-factor recursive least squares (RLS), where the affine term separates constant operating-point and quasi-static mismatch effects from dynamic coefficients. The RST polynomials are recomputed online through a Diophantine equation, with an integral factor included for offset rejection and constant-reference tracking. The controller is experimentally evaluated on a buck converter prototype and compared with a fixed-gain proportional–integral (PI) controller under start-up, load-resistance transitions, and input-voltage transitions. In the start-up test, inductor-current overshoot is reduced from 62.5% to 12.5%, and start-up time decreases from 16.7ms to 1.6ms. For the 48V to 70V input-voltage transition, voltage overshoot decreases from 6.7V to 0.2V. The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nonlinear Control and Current-Sensorless Online Load Estimation of a Buck ConverterMathematics · 2026
- Relative-Degree-Based Discrete-Time Linear Active Disturbance Rejection Control of a Zeta Converter for Wide Input Voltage Range Photovoltaic ApplicationsElectronics · 2026
- Output Voltage Control of a Half-Bridge LLC Resonant Converter Based on Nonsingular Fast Terminal Sliding Mode Active Disturbance Rejection ControlEngineering Research Express · 2026
- Learning Higher Order DC-DC Converter Control from InversionarXiv · 2026
- Disturbance Observer‐Based Dynamic Sliding Mode control for Voltage Regulation of Buck ConvertersAsian Journal of Control · 2026
- Flatness-based Neural Network Control of DC-DC ConvertersarXiv · 2026