Comparative Assessment of R744-Based Cascade Refrigeration Systems with Advanced Exergy Analysis and Annual Performance Evaluation for Three Turkish Cities
Ayşe Fidan Altun
Key points
From the paper's conclusion- These findings support sustainable refrigerant selection through joint consideration of efficiency, emissions, cost, and component improvement potential.
Abstract
This study presents a comprehensive energetic, exergetic, advanced exergetic, economic, environmental, and climate-dependent assessment of a cascade refrigeration system. R744 is employed in the low-temperature cycle, while R134a, R404A, R1234yf, R717, R290, and R152a are comparatively evaluated in the high-temperature cycle. The effects of LTC condensation temperature and cascade temperature difference are investigated with respect to COP, exergy efficiency, total cost rate, and TEWI. Among the investigated refrigerants, R744/R152a provides the most favorable overall performance, achieving a maximum cycle COP of approximately 1.52 and an exergy efficiency of 34.8% at a cascade condensation temperature of about −14 °C, whereas R744/R717 provides the lowest total cost rate at a cascade temperature difference of 5 K. R744/R152a yields a TEWI of 1718 t CO2-eq, which is 25.34% lower than R744/R404A. Increasing the cascade temperature difference from 3 to 12 K decreases its COP from 1.591 to 1.279 and the heat-exchanger area from 31.67 to 12.52 m2. Advanced exergy sensitivity analyses yield avoidable shares of 59.68–71.46%, consistently identifying the HTC compressor as the leading improvement target. Annual system COP values are 1.57, 1.73, and 1.77 for İzmir, Ankara, and Hakkari, with corresponding TEWI values of 1508.4, 1374.6, and 1341.5 t CO2-eq, respectively. These findings support sustainable refrigerant selection through joint consideration of efficiency, emissions, cost, and component improvement potential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive Exergy and Exergoeconomic Analyses and Optimization of a Three-Stage Cascade Refrigeration System Using Environmentally Friendly Refrigerants.Entropy (Basel, Switzerland) · 2026
- Thermodynamic Comparison of Two- and Three-Stage Cascade Refrigeration Systems: A Dynamic Energy Assessment in Hospital EnvironmentsEnergies · 2026
- Thermal performance evaluation of low-GWP refrigerant pairs in cascade refrigeration systems: An experimental and simulation studyInternational Communications in Heat and Mass Transfer · 2026
- Exergetic and performance assessment of superheated vapor compression refrigeration systems under variable compressor efficiency using conventional and low-GWP refrigerantsInternational Journal of Air-Conditioning and Refrigeration · 2026
- Experimental investigation of split air conditioning unit: exergy and total equivalent warming impact analysis using R32 and R290 instead of refrigerant R410AInternational Journal of Air-Conditioning and Refrigeration · 2026
- Thermodynamic analysis of a dual-nozzle ejector enhanced refrigeration cycle for domestic refrigerator/freezer applicationApplied Thermal Engineering · 2026