Validation of View-Specific Markerless Motion Analysis for Lower-Extremity Kinematics After Anterior Cruciate Ligament Reconstruction
Ayaka Tanaka, Issei Ogasawara, Akira Tsujii, Shuma Kinoshita, Kosuke Kitanishi, Shuto Yamashita, Taro Akimori, Toshitaka Tsunematsu,
Key points
From the paper's conclusion- We compared a markerless system (SPLYZA Motion) with optical motion capture (OptiTrack) during single-leg squat (SQ; 15 patients) and single-leg drop-jump landing (DJL; seven patients) after ACL reconstruction.
Abstract
Accurate evaluation of lower-extremity kinematics after anterior cruciate ligament (ACL) reconstruction is important for return-to-sport assessment. Markerless motion capture offers a portable alternative to optical motion capture, but its accuracy across joint rotations and tasks remains uncertain. We compared a markerless system (SPLYZA Motion) with optical motion capture (OptiTrack) during single-leg squat (SQ; 15 patients) and single-leg drop-jump landing (DJL; seven patients) after ACL reconstruction. Sagittal- and frontal-plane angles were analyzed from lateral and anterior camera views, respectively; thus, accuracy reflects view-specific conditions. Root mean square error (RMSE), intraclass correlation coefficients (ICC(A,1)) for range of motion (ROM), and waveform Pearson correlations (r) were evaluated for five joint rotations. Without offset correction, ICC values were 0.78–0.93 for hip and knee flexion/extension, 0.47–0.79 for ankle dorsiflexion/plantarflexion, and 0.03–0.30 for hip adduction/abduction and knee varus/valgus. Pearson’s r values were 0.77–0.99 for sagittal-plane rotations and 0.07–0.58 for frontal-plane rotations. Trial-specific offset correction reduced RMSE without changing ROM-based ICC, but the RMSE improvement was largely lost when offsets were estimated from other participants. Markerless analysis shows clinical potential for sagittal-plane ROM during SQ and hip flexion/extension during DJL, whereas other measurements, particularly frontal-plane ROM, require caution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of markerless motion capture in assessing sagittal-plane lower limb kinematics during running: a systematic review and meta-analysis.Frontiers in bioengineering and biotechnology · 2026
- Markerless motion capture for running: validity and reliability of whole-body, joint, and muscle kinematicsJournal of Biomechanics · 2025
- From linear to nonlinear gait measures: validity of a multi-view markerless motion capture systembioRxiv · 2026
- Markerless Motion Capture in Sport and Exercise: A Systematic Review of Applications, Validity, and ReliabilityApplied Sciences · 2026
- Concurrent Validation of a Multi-Camera Markerless Motion Capture System Against Inertial Sensors for Upper- and Lower-Limb Joint Kinematics.Sensors (Basel, Switzerland) · 2026
- Markerless 3D motion capture in return to sport decision making for ACL injured high level athletes: a narrative review with proposed clinical implementation pathway.Annals of joint · 2026