Probe Wave Parameter Optimization for Vibro-Acoustic Modulation in Bolt Loosening Monitoring.
Shengyu Peng, Yu Wang, Peng Xu
Rocket Force University of Engineering, Xi'an 710025, China.
Key points
From the paper's conclusion- Therefore, optimizing the sweep rate is crucial for enhancing the identification accuracy of incipient bolt loosening.
Abstract
Bolted joints, as critical load-transferring components in large-scale equipment, require effective loosening monitoring to ensure structural safety. Vibro-acoustic modulation (VAM) has attracted considerable attention in bolt loosening monitoring due to its high sensitivity to contact-type defects, yet the influence of fundamental probe wave parameters remains insufficiently explored. In this paper, a theoretical relationship among the modulation amplitudes of the transmitted and reflected waves, the interface pressure, and the probe wave frequency was established based on contact acoustic nonlinearity (CAN) theory. Two complementary modulation indices, a logarithmic index and an integral-based index, were constructed, and systematic experiments on a bolted joint were conducted to analyze the influence of probe wave parameters. The results demonstrate that the logarithmic modulation index offers better stability than the integral-based one. A lower sweep rate is the primary factor in suppressing phase-induced background noise and improving the stability of the modulation index. While a wider swept-frequency range provides a more comprehensive response, it inherently increases the sweep rate under a fixed duration, leading to severe noise near the pump frequency. Therefore, optimizing the sweep rate is crucial for enhancing the identification accuracy of incipient bolt loosening. Theoretically, the frequency dependence is non-monotonic due to the stiffness-impedance balance, and an optimum frequency range exists. However, higher probe frequencies are inferred to induce a spatial focusing effect toward the central high-pressure zone, which significantly enhances the separation of modulation indices under different bolt torques. Moreover, the observed frequency-selective band (140-160kHz) is attributed to a local structural wave-trapping effect at the lap joint, which significantly amplifies the contact acoustic nonlinearity. By tuning the probe wave within this localized resonant band and controlling the sweep rate, the monitoring sensitivity is substantially improved, providing explicit practical guidelines for probe parameter selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Interpretable Frequency–Domain Volterra Nonlinear Feature for Bolt Damage Detection and Preload Identification in Bolted JointsApplied Sciences · 2026
- A method for multi-frequency guided wave response characterization and tightness assessment of bolted joint structuresMechanical Systems and Signal Processing · 2026
- Order-normalized multi-speed bolt loosening diagnosis under leakage-aware evaluationJournal of Physics: Conference Series · 2026
- Bolt Loosening Detection Techniques for Transmission Tower Member Systems: Framework, Trends, and ChallengesEnergies · 2026
- Preload Attenuation Behavior of Bolted Joint Structures Under Transverse VibrationCoatings · 2026
- Corrosion monitoring of bolted connections using active acoustic waves.Ultrasonics · 2026