Ultrasonics

Corrosion monitoring of bolted connections using active acoustic waves.

Seyed Amir Hoseini Sabzevari, Mojtaba Vakili-Azghandi

Department of Mechanical Engineering, Faculty of Engineering, University of Gonabad, Gonabad, Iran. Electronic address: Hoseini.sabzevari@gonabad.ac.ir. · Department of Materials Engineering, Faculty of Engineering, University of Gonabad, Gonabad, Iran.

Key points

From the paper's conclusion
  • The results indicate that the proposed framework can effectively discriminate sequential monitoring stages associated with corrosion progression under the investigated experimental conditions.

Abstract

Corrosion of bolted connections gradually alters the mechanical integrity of engineering structures, making reliable monitoring essential for condition-based maintenance. This study proposes an acoustic sensing based approach for monitoring corrosion progression in bolted joints subjected to accelerated electrochemical corrosion. A controlled corrosion platform was developed in which a single-lap bolted joint was exposed to a 3.5 wt% NaCl solution under an externally applied DC voltage. To independently quantify corrosion progression, a companion specimen was prepared for periodic mass-loss measurements throughout the 120 h exposure period. Frequency-domain analyses revealed that the most pronounced acoustic-response changes observed during corrosion progression were concentrated primarily within the 4-8 kHz frequency range. Consequently, wavelet packet decomposition was applied to this frequency band, and wavelet energy features were extracted for each measurement stage. Principal component analysis and Fisher Score evaluation showed that discriminative information was concentrated within a limited number of localized frequency bands. Finally, a multi-class support vector machine (SVM) classifier with stratified 10-fold cross-validation was employed to distinguish fifteen sequential monitoring stages. Among the fixed configurations compared, the 4-8 kHz, Level-8 WPD representation achieved a mean accuracy of 96.81 %, with macro-averaged Precision, Recall, and F1-score all exceeding 96 %. The confusion matrix showed that most classifications were concentrated along the diagonal, although a small number of non-adjacent misclassifications were also observed. The results indicate that the proposed framework can effectively discriminate sequential monitoring stages associated with corrosion progression under the investigated experimental conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers