Thermographic Sensing for Biomedical Electronic Circuits: Sensor Selection, Acquisition Requirements, and Emissivity Compensation.
Filippo Laganà
Laboratory of Biomedical Applications Technologies and Sensors (BATS), Department of Health Science, "Magna Græcia" University, 88100 Catanzaro, Italy.
Key points
From the paper's conclusion- This focused critical review examines the literature linking infrared detector selection and acquisition requirements with radiometric calibration and emissivity compensation.
Abstract
Infrared thermography can support inspection and monitoring of electronic circuits used in biomedical devices, but heterogeneous emissivity, reflected radiation, optical averaging, and instrument drift complicate temperature interpretation. This focused critical review examines the literature linking infrared detector selection and acquisition requirements with radiometric calibration and emissivity compensation. Published implementations are compared using their reported array formats, spectral bands, acquisition conditions, and measurement quantities, without treating sensitivity, spatial resolution, and temperature accuracy as equivalent metrics. Reference-based characterization, pixel-level correction, material recognition, and spectral or temporal processing are assessed according to their assumptions and validation needs. The synthesis distinguishes direct biomedical evidence from transferable methods developed for general electronics and infrared metrology. For biomedical circuits, measurement validity must be related to optical access, device operating state, and independently assessed electrical or functional conditions. Three research priorities emerge: uncertainty-qualified characterization of heterogeneous surfaces, spatial and thermal validation of the complete acquisition system, and diagnostic evaluation across independent devices and operating sessions. The proposed framework connects these priorities to measurable validation outcomes, with embedded processing and artificial intelligence assessed as components of the complete measurement chain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Emerging Trends and Applications in Thermal Imaging Using Infrared Detectors: A ReviewIEEE Sensors Journal · 2025
- Emissivity Correction Changes the Maintenance Decision: Reference-Free Validation of Material-Resolved Severity Grading in Proximal Thermal Remote Sensing of High-Voltage Substations.Sensors (Basel, Switzerland) · 2026
- La importancia de la electrónica discreta en aplicaciones biomédicas: fiabilidad, verificabilidad y resiliencia tecnológica en sistemas críticos de saludLATAM Revista Latinoamericana de Ciencias Sociales y Humanidades · 2026
- An Intelligent Multi-Emissivity Infrared Temperature Correction Method for Substation Equipment Based on Semantic Segmentation.Sensors (Basel, Switzerland) · 2026
- Bioelectronics beyond proof-of-concept demonstrationAPL Electronic Devices · 2026
- Dynamic Infrared Thermography for Quantitative Assessment of Peripheral Microcirculation: Models, Metrics, and Clinical TranslationPhysiological Measurement · 2026