Data-Driven Calibration and Reference-Free Drift Detection for Multi-Modal Sensor Systems.
Kishor Arvind Mohandas Sivakumar, Laurent Segers, Bruno da Silva, Argha Sen, Sujay Narayana, R R Venkatesha Prasad
Electrical Engineering, Mathematics and Computer Science Department, TU Delft, 2600AA Delft, The Netherlands. · Department of Electronics and Informatics, Vrije Universiteit Brussel, 1050 Brussels, Belgium.
Key points
From the paper's conclusion- Together, these results give a transparent, reproducible baseline and clear practical guidance for building trustworthy low-cost sensor networks.
Abstract
Low-cost multi-modal sensors make high-resolution exposomic and urban-health monitoring affordable, but their data are only as useful as they are trustworthy. Measurement bias, cross-sensitivity, temporal drift and domain shift between devices and sites erode reliability, and reference instruments are rarely available for every sensor. We present a two-part reliability workflow for this realistic setting, in which reference data exist for only a subset of sensors, and evaluate it on five custom multi-modal devices deployed at two Brussels sites (9 to 68 days of data per device). For calibration, we benchmark Multiple Linear Regression, Elastic Net, Random Forest, Gradient Boosting and a Domain Adversarial Neural Network (DANN) for O3, NO2, PM2.5 and PM10 on the source device and on other devices at the same site and at the other site using MAE, RMSE, R2, bias, device-balanced aggregation and block-bootstrap intervals. Tree ensembles achieve the lowest source-device errors for most pollutants, yet for PM10, they lose their advantage over the uncalibrated sensor when transferred, a caution for any deployment that calibrates on one unit. DANN attains the highest mean Calibration Transfer Ratio in the transfer settings, although with the available device pairs, the differences are not statistically significant. For modalities without a reference, a cross-sensor residual monitor combined with statistical detectors reliably flags injected gradual drift in sensors that can be reconstructed from the others (UV bands, PM1, temperature, humidity and CO), while Lux, pressure and VOC remain harder. The monitor detects cross-sensor inconsistency rather than isolating the faulty sensor, and the results reflect an injected fault model, not real sensor ageing. Together, these results give a transparent, reproducible baseline and clear practical guidance for building trustworthy low-cost sensor networks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A review of machine learning approaches for improving calibration and performance of low-cost air quality sensor networksSensor Review · 2026
- Low-Cost Sensor Calibration for Indoor Air Quality Monitoring: A Dataset, Evaluation Scenarios, and a Lightweight ModelarXiv · 2026
- Machine Learning Calibration Transfer for Low-Cost Air Quality Sensors: Distance-Based Uncertainty Quantification in a Hybrid Urban Monitoring NetworkAtmosphere · 2026
- Machine Learning-Enhanced Calibration Algorithm for Drift Compensation in Long-Term Electrochemical Environmental Monitoring NetworksAnalytical Letters · 2026
- How Accurate Are Low-Cost Air Quality Sensors? A 10-Month Study of Three-Tier Comparison with Three Calibration Methods and Cross-Site Transferability.Sensors (Basel, Switzerland) · 2026
- Enhancing Accuracy of Indoor Air Quality Sensors via Automated Machine Learning CalibrationAtmospheric measurement techniques · 2026