Evaluation and Remediation of Data Quality for Drilling-Fluid Property Online Monitoring.
Qi Lu, Zhilin Li, Dongxiao Pang
Drilling and Production Engineering Technology Research Institute, Chuanqing Drilling Engineering Co., Ltd., CNPC, Chengdu 610000, China.
Key points
From the paper's conclusion- We validate an evaluation–marking–remediation–validation workflow on a multi-source database of about 500,000 business records and on 150,000 instrument and replay records that are registered separately by source and are not summed, from five wells.
Abstract
Missing values, outliers, out-of-order timestamps, unit inconsistencies and baseline drift degrade online monitoring data on drilling-fluid properties in deep wells. We validate an evaluation-marking-remediation-validation workflow on a multi-source database of about 500,000 business records and on 150,000 instrument and replay records that are registered separately by source and are not summed, from five wells. Six metrics describe data quality: missing rate, out-of-order rate, outlier rate, unit consistency, baseline drift and noise. Missing values are treated in tiers: short gaps are interpolated, medium gaps are interpolated as last-observation-carried-forward with a mask, and long gaps invalidate the window. Offline filling uses forward filling, linear interpolation or random forest prediction. MAD/Hampel detection with operating-condition matching separates sensor artefacts, operational transients and genuine anomalies. Signal enhancement combines robust denoising, multi-scale fusion and a trend-confidence threshold. On the same replay dataset, the missing rate fell from 6.8% to 0.7%, the outlier rate decreased from 3.6% to 0.8%, the baseline-drift index fell from 1.47 to 0.61, the noise level decreased by 40.8%, and the usable-record ratio rose from 77.0% to 98.0%. On a fixed judgement set of 55 genuine events and 164 negative exposure intervals, the operator that retains operations and multi-metric co-movement recovered 55 of 55 genuine events at a negative-interval false alarm rate of 25.61%, against 0% recall for the 3-sigma rule and 54.55% recall for Hampel alone; this comparison covers simplified cleaning operators and is not equivalent to the complete remediation chain. Warning models trained on the remediated data reached an F1 of 93.0-94.0% and lead times of 1.8-2.8 h on the replay test dataset. The raw data replay and the field application are two different data sources and are not compared as an effect of remediation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fuzzy Fault Detection and Band-Conditioned Data Quality Assessment for Sensor Streams: A Continuous Glucose Monitoring Case Study.Sensors (Basel, Switzerland) · 2026
- Text-Informed Training Data Filtering for Enhanced Virtual Flow Meter PerformancearXiv · 2026
- Distinguishing Process Change, Instrument Fault and Data-Path Corruption in Streaming Telemetry: A Reference Implementation and BenchmarkarXiv · 2026
- Review on deep learning-assisted soft sensors using imperfect measurementsMeasurement Science and Technology · 2026
- Scale adaptability of filtering and unsupervised identification of measurement-while-drilling signals in fractured rock massesFrontiers in Earth Science · 2026
- A collaborative multi-model framework with large language model fusion for automated reservoir model quality assuranceScientific Reports · 2026