CdS/rGO Nanocomposite for Sensitive Electrochemical Detection of Copper Ions.
Muhammad Sajid Shafiq, Fabian O Romero-Soto, Martín F Jiménez-Moreno, Amritha Kadathamana, Masoud Madadelahi, Marc J Madou, Josué Amilcar Aguilar Martínez, Rudra Kumar
School of Engineering and Sciences, Tecnologico de Monterrey, Av. Eugenio Garza Sada 2501 Sur, Monterrey 64849, NL, Mexico. · Centro de Investigación e Innovación en Ingeniería Aeronáutica (CIIIA), Facultad de Ingeniería Mecánica y Eléctrica, Universidad Autónoma de Nuevo León, Carretera a Salinas Victoria km. 2.3, Apodaca 66600, NL, Mexico.
Key points
From the paper's conclusion- These results highlight the potential of the CdS/rGO-based sensor as a reliable and sensitive platform for the practical electrochemical detection of Cu2+ ions.
Abstract
A highly sensitive and selective electrochemical sensor for Cu2+ ions was fabricated by modifying a glassy carbon electrode (GCE) with a CdS/rGO nanocomposite. The structural and morphological characteristics of the synthesized materials were thoroughly investigated using Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy. These analyses confirmed the synthesis of the CdS/rGO nanocomposite via a hydrothermal synthesis route. The electrochemical performance of the modified electrode was systematically evaluated using cyclic voltammetry (CV), differential pulse anodic stripping voltammetry (DPASV), and electrochemical impedance spectroscopy (EIS). The CdS/rGO-modified electrode exhibited enhanced electrocatalytic activity, with well-defined anodic and cathodic peak currents that demonstrated a linear relationship with the square root of the scan rate over the range of 50-250 mV s-1. Under optimized conditions, the sensor demonstrated appropriate analytical performance over a Cu2+ concentration range of 10-100 nM, with a remarkably low limit of detection (LOD) of 2.83 nM. Furthermore, the sensor exhibited good selectivity toward Cu2+ in the presence of various interfering ions, along with good reproducibility and long-term operational stability. Its practical applicability was further demonstrated through the successful determination of Cu2+ ions in water samples and complex matrices, yielding satisfactory recovery values. These results highlight the potential of the CdS/rGO-based sensor as a reliable and sensitive platform for the practical electrochemical detection of Cu2+ ions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced Cadmium Detection in Real Water Sources Using a Custom Nanocomposite-Modified Carbon Electrode and Optimized Square Wave Voltammetry.Sensors (Basel, Switzerland) · 2026
- Dual fluorescence and absorbance sensing of Cu2+ and Pb2+ ions using plasma-engineered carbon quantum dots.Analytical methods : advancing methods and applications · 2026
- Spinel Cobalt-Copper Sulfide Nanoparticle-Based Electrochemical Sensor for Ultrasensitive Detection of Toxic Cu²⁺ and Hg²⁺ IonsJournal of The Electrochemical Society · 2025
- Electrochemical Sensor Based on Polydopamine-Coated Silver Nanowire/Defect-Ridden UiO-66-NH₂ Nanocomposites for Trace Detection of Cd(II) and Pb(II) Ions in WaterACS Applied Nano Materials · 2025
- An electrochemical sensing of Pb2+ and Cu2+ using a covalent organic polymer and multi-walled carbon nanotubes modified glassy carbon electrode in food samplesJournal of Food Composition and Analysis · 2025
- Self-Powered PEC Cathodic Immunosensor for CA125 Detection Based on the Cu₂ O Photocathode and the CdS/PANI PhotoanodeACS Sensors · 2025