Enhanced Cadmium Detection in Real Water Sources Using a Custom Nanocomposite-Modified Carbon Electrode and Optimized Square Wave Voltammetry.
Dipen Basnet, Rohit Boddu, Xiyuan Liu, Prabhu U Arumugam, Shabnam Siddiqui
Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA. · Department of Mathematics and Statistics, Louisiana Tech University, Ruston, LA 71272, USA.
Key points
From the paper's conclusion- We found that the LOD and the full width at half maximum of the Cd2+ peak are dependent on frequency, while sensitivity and peak resolution depend on amplitude and step potential.
Abstract
Monitoring toxic heavy metals in complex, real water sources is essential for safe water supplies. Current sensors lack the sensitivity, selectivity, and limits of detection (LOD) needed to detect heavy metals such as cadmium (Cd2+) in real water samples with minimal preparation. Here, we demonstrate a novel ternary nanocomposite-coated carbon electrochemical sensor that detects Cd2+ with the highest sensitivity (14.71 ± 0.3, 6.94 ± 0.8 μA·ppb-1·cm-2) and the lowest LODs (0.06 ± 0.02, 0.61 ± 0.10 ppb) in spiked deionized and lake waters, respectively. Sensor fabrication optimization included electrochemical polishing of carbon screen-printed electrodes, surface modification with a 1 mg/mL bismuth-reduced graphene-molybdenum disulfide nanocomposite ink, and rapid heating and cooling at 75 °C for 3 min. These steps, along with square wave anodic stripping voltammetry (SWASV) deposition potential identification, produced distinct detection peaks and high reproducibility (8% RSD). We further investigated the SWASV parameters, specifically frequency (5 to 50 Hz), amplitude (1 to 100 mV), and step potential (5 to 70 mV), using a fast causal inference algorithm, which resulted in a 233-fold increase in Cd2+ sensitivity. We found that the LOD and the full width at half maximum of the Cd2+ peak are dependent on frequency, while sensitivity and peak resolution depend on amplitude and step potential. Under optimal detection conditions of 35 Hz, 60 mV amplitude, and a 10 mV step potential, the sensor showed adequate sensitivity and LODs, even in the presence of 10-fold concentrations of Zn2+, As3+, and Cu2+ as interferents, confirming its suitability for real-world water-quality field testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CdS/rGO Nanocomposite for Sensitive Electrochemical Detection of Copper Ions.Sensors (Basel, Switzerland) · 2026
- Electrochemical determination of Cd2⁺ using an NH2-UiO-67/carbon black composite modified electrode.Analytical and bioanalytical chemistry · 2026
- Detection of Cd2+ and Pb2+ in egg yolk and maize samples by a novel SDA/MWCNTs-based electrochemical sensor.RSC advances · 2026
- Sustainable waste-derived carbon/Bi2O3-Sm ternary composite for sensitive electrochemical detection of Pb2+ and Cd2+ ions in surface water.Analytical and bioanalytical chemistry · 2026
- Heavy Metal Ion Detection by Carbonized Metal–Organic–Framework (MOF-C) Nanocomposite-Modified Electrochemical SensorsChemosensors · 2026
- Spinel Cobalt-Copper Sulfide Nanoparticle-Based Electrochemical Sensor for Ultrasensitive Detection of Toxic Cu²⁺ and Hg²⁺ IonsJournal of The Electrochemical Society · 2025