Isolating the Contributions of Resistance-Ratio Normalization and Humidity Fusion in a Minimal Three-Sensor Electronic Nose.
Tharun H Nambi, Nikhil Bhimireddy, Joseph P McElroy
Olentangy Orange High School, Lewis Center, OH 43035, USA. · Program in Liberal Medical Education, Brown University, Providence, RI 02912, USA.
Key points
From the paper's conclusion- We isolate each on a three-sensor MQ array across nine pure headspaces.
Abstract
Low-cost metal oxide semiconductor (MOS) electronic noses often combine resistance-ratio (Rs/R0) normalization with a humidity transducer, both from the outset, so neither is measured. We isolate each on a three-sensor MQ array across nine pure headspaces. On one device the voltage-to-resistance step is monotone, so on 245 trials with per-trial clean-air baselines, the whole effect is the R0 division: it cost a random forest 3.8 percentage points (seed-sweep interval 2.3-5.3) and linear models 8-9 points, possibly inflated by incomplete baseline recovery, and left the dominant error mode, a symmetric glycerol-water confusion, untouched. In-chamber humidity, from a channel withheld from the classifier, points to a physical rather than signal-conditioning origin. Admitting humidity as a fourth feature raises accuracy from 90.2 to 99.3% (450 trials, ten seeds, p < 10-8) and from 86.7 to 93.3% under a cross-day holdout; temperature and equivalent CO2 (eCO2) do not. A leave-one-sensor-out test shows MQ-9 adds 0.89 ± 0.63 points on three channels and nothing with humidity admitted, so two MOS channels and humidity suffice here. The contribution is the matched ablation, not the accuracy: we propose, for MOS arrays sampling aqueous preparations, adding a transducer for the interferent rather than transforming channels that cannot resolve it.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Disentangling Response Magnitude and Relative MOS Sensor Fingerprints for Electronic-Nose Screening of Off-Odor in Table Olives.Sensors (Basel, Switzerland) · 2026
- Development of a Calibration Transfer Methodology and Experimental Setup for Urine Headspace AnalysisChemosensors · 2025
- Data-Driven Approach toward the Quantification of Gases in a Complex Mixture Using a Non-Selective Single Metal Oxide Gas SensorACS Sensors · 2026
- Temperature and humidity compensation improves PANI/SnS 2 ammonia concentration predictionREVIEWS ON ADVANCED MATERIALS SCIENCE · 2026
- Compensation of Ambient Variations in a Temperature-Modulated SnO2 Gas Sensor-Based Electronic Nose for Accurate Discrimination of Structurally Similar Volatile Organic Compounds.ACS sensors · 2026
- MBWCT-Net: Multiscale Transient Learning for Early Discrimination of Wood-Extracted VOC Mixtures via an Electronic Nose.ACS sensors · 2026