All-Solid-State Ion-Selective Electrodes with Multi-Walled Carbon Nanotubes Based on Glassy Carbon for Biguanide Derivative (Chlorhexidine Digluconate).
Joanna Lenik, Katarzyna Witkowska
Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Square 3, 20-031 Lublin, Poland.
Key points
From the paper's conclusion- 10 s, potential stability (the potential drift is several dozen μV min−1 in a 10−4 mol L−1 chlorhexidine solution over 4 h), and high potential reversibility (the standard deviation in a 10−5 mol L−1 solution is 0.69 mV, whereas in a 10−4 mol L−1 solution it is 0.71 mV) are further advantages and benefits of the developed modern electrodes.
Abstract
This paper presents research on the properties of solid contact electrodes with an intermediate layer of multi-walled carbon nanotubes. They were used as an intermediate layer (Solid Contact SC-ISE electrodes) and as a dispersed material in a polymer membrane (Single Piece SP-ISE electrodes). The properties of neutral macrocyclic compounds as active ion-sensitive substances in membranes, in which plasticizers with varying lipophilicity were also used, were compared. The selected optimal sensor shows a theoretical Nernstian response for the divalent chlorhexidine ion (z = 2) of approximately 29 mV decade-1 over the linearity range of 10-6-10-3 mol L-1. A short response time of approx. 10 s, potential stability (the potential drift is several dozen μV min-1 in a 10-4 mol L-1 chlorhexidine solution over 4 h), and high potential reversibility (the standard deviation in a 10-5 mol L-1 solution is 0.69 mV, whereas in a 10-4 mol L-1 solution it is 0.71 mV) are further advantages and benefits of the developed modern electrodes. In general, it can be concluded that the SC-ISE showed better potential reversibility than the SP-ISE, particularly at chlorhexidine concentrations of 10-4 and 10-5 mol L-1, while also exhibiting improved resistance to water-layer formation. High selectivity was also achieved in relation to ionic substances (sodium, potassium, calcium, magnesium, acesulfame ions, and neutral substances used as excipients in chlorhexidine preparations, i.e., d-mannitol, d-sorbitol, sucralose, propylene glycol, xylitol, aspartame). The sensor with satisfactory parameters was used to determine the API content in the pharmaceutical preparation, Eludril, with a recovery of 95.9-98.6% and a relative standard deviation (RSD) ranging from 0.7 to 3.7%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reference Electrode‐Free Nitrate Sensing via Differential Temperature‐Modulated Potentiometry in Printed Symmetric SC‐ISEsAdvanced Electronic Materials · 2026
- Composition and Fabrication of Chalcogenide Glass Membranes for Chloride Sensing and Automated MonitoringInternational Journal of Applied Glass Science · 2026
- Precision Engineering of PVC‐Carbon Allotrope Interactions for Advanced Potassium Ion Sensors: Achieving High Sensitivity and Long‐Term StabilityElectroanalysis · 2026
- Solid‐Contact Copper(II)‐Selective Potentiometric Sensor Based on a Newly Synthesized Thiazole–Phenylurea Derivative MoleculeChemistrySelect · 2026
- Long-time measurements of calcium release by dental resin-based composites using a liquid-contact calcium ion-selective electrode.Analytical and bioanalytical chemistry · 2026
- Synthesis of new rhodanine derivative molecules, their biological properties and sensor applications in environmental samplesBMC Chemistry · 2026