From the paper's conclusion- These results establish a dependence on composition and fabrication route, although the origin of the strongly sub‐Nernstian response remains unresolved.
Abstract
Chalcogenide‐glass‐based ion‐selective electrodes were developed and evaluated for chloride‐ion detection using Ag X –Ag 2 S–As 2 S 3 ( X = Cl or Br) glass membranes. Six different glass compositions were synthesized by melt‐quenching and used as ion‐sensitive membranes in two electrode configurations: glass‐slice sensing (GSS) and glass‐pellet sensing. The electrochemical performance of the fabricated electrodes was investigated in terms of potentiometric response, sensitivity, limit of detection, and long‐term stability. GSS‐C#8, with nominal composition (AgBr) 0 . 5 (Ag 2 S) 0 . 25 (As 2 S 3 ) 0 . 25 , gave the best overall performance among the tested electrodes. Its response slope magnitude was 13.8 ± 0.5 mV per decade initially and 11.5 ± 0.8 mV per decade after 30 days of storage in 0.1 mol L −1 NaCl. The corresponding detection limits reported for the calibration curves were approximately 1.9 × 10 −3 and 1.6 × 10 −4 mol L −1 , respectively. Most pellet‐based electrodes showed weaker or less stable responses. These results establish a dependence on composition and fabrication route, although the origin of the strongly sub‐Nernstian response remains unresolved. Conditioning‐induced surface modification, potentially involving silver‐halide phases, is a possible explanation requiring direct characterization. The selected GSS‐C#8 electrode was incorporated into an Arduino‐controlled flow‐cell prototype, which gave a chloride‐dependent potential with a fitted slope magnitude of 7.0 ± 0.3 mV per decade. The study demonstrates automated measurement with chalcogenide‐derived membranes and identifies surface chemistry, calibration stability, and selectivity as requirements for further development.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Silver–Silver Chloride Reference Electrode: Construction and Performance in Nitrogen-Containing Organic SolventACS electrochemistry. · 2026
- All-Solid-State Ion-Selective Electrodes with Multi-Walled Carbon Nanotubes Based on Glassy Carbon for Biguanide Derivative (Chlorhexidine Digluconate).Sensors (Basel, Switzerland) · 2026
- Effects of substrate roughness on the fabrication and properties of Ag/AgCl pseudo-reference electrodes for solid-state electrochemical sensors.Frontiers in chemistry · 2026
- Surface Characterization of Various Iron Chalcogenide Glass Ion‐Selective Electrode MembranesElectroanalysis · 2026
- Composition-Dependent Density Modeling of Chalcogenide Glasses: Empirical Evidence for Influential van der Waals Interactions and the Central Role of Lone-Pair ElectronsJournal of Optics and Photonics Research · 2026
- From Capture to Sensing: First-Principles Insights into Sb/Ga/In-Modified Janus ZrSSe for Environmental Monitoring of Hazardous Chlorine-Containing Gases.Langmuir : the ACS journal of surfaces and colloids · 2026