Sensors (Basel, Switzerland)

Development of a Wearable Torsion Sensor Utilizing a Geometric Model and a Hysteresis-Compensated Calibration Engine.

Bonhak Koo, Seonghun Yu, Hojong Chang, Chansol Kang, Jeehyun Sim

Digital Industry Division, Korea Dyeing & Finishing Technology Institute, Daegu 41706, Republic of Korea. · Department of National Public Policy, Graduate School, Chungnam National University, Daejeon 34134, Republic of Korea.

Key points

From the paper's conclusion
  • In this single-subject proof-of-concept feasibility study (n = 1), the proposed framework demonstrated the feasibility of continuous torsional motion tracking through a training-free geometric approach, providing a preliminary foundation for future evaluation in wearable systems and soft robotics.

Abstract

Measuring torsional movement is crucial for tracking human kinematics in applications such as virtual reality, biomechanics, rehabilitation, and soft robotic joints. However, continuous, non-invasive torsion measurement remains challenging due to multi-axial deformations, where existing methods rely heavily on empirical data fitting or computationally expensive deep learning models requiring vast training datasets. To address these limitations, this paper proposes a training-free, highly precise torsion estimation framework that converts soft resistive strain sensor data into forearm rotation angles using closed-form kinematic-geometric modeling. Two geometric representations-the Cylinder Model and Truncated Cone Model-are established to analytically map non-linear tensile strain to torsion angles. Additionally, an online calibration algorithm is integrated to mitigate cumulative measurement drift caused by viscoelastic hysteresis. Under static conditions, the proposed models achieved a high coefficient of determination (R2 = 0.9888) against reference IMU data. In dynamic trials, the hysteresis compensation algorithm maintained robust tracking performance (R2 = 0.8033), achieving an angular root-mean-square error (RMSE) of 4.12° and a cycle peak prominence relative error of 0.42% for the Truncated Cone Model. In this single-subject proof-of-concept feasibility study (n = 1), the proposed framework demonstrated the feasibility of continuous torsional motion tracking through a training-free geometric approach, providing a preliminary foundation for future evaluation in wearable systems and soft robotics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers