From the paper's conclusion- The achieved accuracy satisfies clinical requirements for home rehabilitation and validates the system as a comfortable and cost-effective alternative to rigid motion capture technologies.
Abstract
Low-cost stretchable sensors offer promising solutions for wearable joint angle monitoring in home rehabilitation but suffer from viscoelastic hysteresis and relaxation drift. This paper proposes a wearable elbow angle monitoring system achieving high accuracy using only resistive stretch sensors. The system employs a dual-sensor antagonistic configuration and an LSTM network for hysteresis compensation. The antagonistic layout includes a pre-strained inner sensor to eliminate signal dead zones near full extension. A temporary resistive bend sensor provides dynamic ground truth during a one-time calibration phase and is subsequently removed for daily deployment. The neural network learns the history-dependent mapping from corrupted signals to compensated angle estimates. Experimental results demonstrate that the proposed system reduces the hysteresis loop width by 63.8\% and stabilizes estimates despite raw resistance drift. Evaluating random rehabilitation movements yields an RMSE of 6.2$^\circ$ and an $R^2$ of 0.95, representing a 42.0\% accuracy improvement over baseline linear regression. The achieved accuracy satisfies clinical requirements for home rehabilitation and validates the system as a comfortable and cost-effective alternative to rigid motion capture technologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-embedded Multimodal E-skin Enabling Muscle Proprioception.IEEE journal of biomedical and health informatics · 2026
- Textile-Integrated Magnetoinductive Waveguides for Low-Complexity, Single-Channel Quantitative Estimation of Isometric Elbow Torque.IEEE transactions on bio-medical engineering · 2026
- A Brace-Integrated Fiber Bragg Grating Sensor with a Multi-Hardness Silicone Strain Transfer Substrate for Knee Flexion Monitoring: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2026
- A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System.Sensors (Basel, Switzerland) · 2026
- Development of a Wearable Torsion Sensor Utilizing a Geometric Model and a Hysteresis-Compensated Calibration Engine.Sensors (Basel, Switzerland) · 2026
- An Intelligent Braided Armband System for Training Assistance.ACS sensors · 2026