Axial Stress Measurement of Small Diameter Aluminum Alloy Tubes Using a Conformal Oblique Incidence-Guided Wave Probe.
Shuangxu Yang, Chunguang Xu, Yongjiang Ma, Wenjun Zhang
School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China. · Ningbo Branch of China Academy of Ordnance Science, Ningbo 315103, China.
Key points
From the paper's conclusion- The results demonstrate the feasibility of reference based quantitative axial stress evaluation using an established zero-load reference state in small diameter thin-walled aluminum alloy tubes under restricted circumferential access.
Abstract
Quantitative evaluation of axial stress in small diameter thin-walled aircraft tubing is important for characterizing its mechanical state during assembly and service. However, restricted circumferential access necessitates a compact local excitation configuration, for which geometric mismatch between conventional planar acoustic sources and curved tube surfaces can lead to circumferentially nonuniform excitation and interfere with stable time of flight (TOF) estimation. This study proposes a reference-based axial stress measurement method using an L(0,2)-dominated guided wave response generated by a conformal oblique incidence probe. Based on acoustoelastic-guided wave analysis and transient response characteristics, 500 kHz was adopted as an appropriate operating frequency for the present sensing configuration. Three-dimensional finite element simulations showed that the conformal loading configuration produced a more regular circumferential wavefield distribution. Experimental comparisons showed that the amplitude of the strong subsequent response was approximately 91% of the target wave packet amplitude for the conventional planar probe but below 31% for the conformal probe, indicating greater time domain prominence of the target wave packet relative to subsequent responses and providing a more stable waveform basis for TOF estimation. Repeated calibration established an approximately linear relationship between TOF shift and axial tensile stress. Validation tests on tubes from the same batch, together with repeated measurements after probe reinstallation and recoupling, yielded an overall mean absolute deviation from the reference stress of 1.86 MPa and a mean absolute relative deviation of 3.17%. The results demonstrate the feasibility of reference based quantitative axial stress evaluation using an established zero-load reference state in small diameter thin-walled aluminum alloy tubes under restricted circumferential access.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Guided elastic waves for soft elastomer characterization: an alternative to conventional rheometryActa Acustica · 2026
- Influence of Waveguide Characteristics on Acoustic Emission Sensitivity to Defect Depth ChangesSensors · 2026
- evaluating local viscoelastic properties of artery-mimicking phantoms using high-resolution flexural wavenumber analysisarXiv · 2026
- Identification of Pipeline Axial Tensile Stress Using Geometric and ACSM In-Line Inspection Data.Sensors (Basel, Switzerland) · 2026
- Torsional Guided Waves for Simulation of the Pipeline Testing: Frequency Analysis of the SignalsJournal of Vibration Engineering & Technologies · 2026
- Size-dependent interfacial elasticity effects on SH wave propagation in cylindrical structuresPhysica Scripta · 2026