Sensors

Influence of Waveguide Characteristics on Acoustic Emission Sensitivity to Defect Depth Changes

Egor Lepsheev, Vera Barat, Artem Marchenkov, Ivan Lukashev, Vladimir Bardakov, Alexander Alexandrov, Anastasiya Pankina, Roman Agafonov

Key points

From the paper's conclusion
  • The results show that the permissible distance at which the method retains sensitivity to depth changes is 0.3 m for 4 mm plates, 1.5 m for 8 mm plates, and 5 m for 16 mm plates.

Abstract

Acoustic emission (AE) is widely used for monitoring critical industrial facilities: pipelines, pressure vessels, and storage tanks. At the frequencies used in AE testing, these structures could be considered as thin-walled waveguides, and the signals propagate as Lamb waves. A key problem in monitoring is the assessment of defect depth. Unlike other non-destructive testing methods, AE cannot directly measure the absolute defect depth, but it can detect its growth by analyzing the dynamics of the energy ratio of the symmetric (S0) and antisymmetric (A0) Lamb modes within a sequence of AE signals. Due to the dispersive nature and frequency-dependent attenuation of Lamb waves, the waveform and spectrum depend strongly on the distance propagate through the waveguide. This complicates the interpretation of AE data, since the influence of the acoustic waveguide masks the source parameters and hinders the identification of defect hazard. This study analyzes the transformation of AE signals during their propagation along the waveguide to determine the source–sensor distance at which sensitivity to defect depth changes is preserved. The research uses a dataset of model signals generated by the semi-analytical finite element (SAFE) method, which accounts for viscoelastic attenuation and the sensor transfer function. The results show that the permissible distance at which the method retains sensitivity to depth changes is 0.3 m for 4 mm plates, 1.5 m for 8 mm plates, and 5 m for 16 mm plates. At these distances, the minimum detectable depth increment is 0.25wt for 4 mm plates and 0.5wt for 8 and 16 mm plates. These estimates define practical upper bounds for sensor spacing in AE-based structural health monitoring systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of Waveguide Characteristics on Acoustic Emission Sensitivity to Defect Depth Changes — Science Skim