Array-Based CTD Thermal Sensing for Low-Flow Downhole Applications with Dual-Mode Compensation.
Zihan Lin, Yong Wei, Yifei Zhang, Ruyi Gan, Mei Wang, Qiang Chen
School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China. · China Petroleum Logging Co., Ltd., Xi'an 710077, China.
Key points
From the paper's conclusion- These results demonstrate the feasibility of the integrated array-based CTD sensing and compensation framework for stable multipoint thermal response characterization under controlled low-flow conditions.
Abstract
Accurate downhole temperature sensing and low-flow characterization remain challenging in horizontal and highly deviated wells because of nonuniform cross-sectional flow, temperature drift, and probe-to-probe response differences. This study develops an array-based dual-mode constant-temperature-difference (CTD) sensing system for low-flow downhole applications. The system integrates one upstream temperature-sensing probe and six downstream heated sensing probes with pulse width modulation (PWM)-based CTD regulation, particle swarm optimization-genetic algorithm-proportional-integral-derivative (PSO-GA-PID) parameter tuning, probe-specific polynomial calibration, and depth-matched baseline compensation. The resulting framework is intended to improve the heating stability and consistency of the distributed thermal responses. Simulations using representative CTD thermal dynamics, together with repeated stochastic optimization, show that PSO refinement improves the repeatability of PID parameter tuning and reduces transient deviation. Experimental tests further show that PSO-GA-PID achieves a mean overshoot of 4.34% and a mean integral of time-weighted absolute error (ITAE) of 807.08, both lower than those of GA-PID. After polynomial calibration, the absolute temperature errors of all probes remain within ±0.6 °C over 10-60 °C and ±0.3 °C over 60-150 °C. Under single-phase water conditions, dual-mode baseline compensation reduces the maximum duty-cycle difference among the six sensing probes from 6.1-7.6 to 2.6-4.0 percentage points. The compensated heating duty cycle increases monotonically with flow rate and exhibits higher sensitivity over 0-30 m3/d than over 30-60 m3/d, providing a measurable basis for subsequent flow-rate calibration. Additional water-cut experiments show that the duty-cycle-flow relationship depends on fluid composition, indicating the need for composition-specific calibration under oil-water two-phase conditions. These results demonstrate the feasibility of the integrated array-based CTD sensing and compensation framework for stable multipoint thermal response characterization under controlled low-flow conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temperature control model analysis of intelligent drilling fluid surface cooling equipment for high-temperature deep well working conditionsJournal of Physics: Conference Series · 2026
- A relative injection profile identification method based on distributed temperature sensingFrontiers in Earth Science · 2026
- Physics-Informed Neural Network-Based Inversion of Distributed Temperature Sensing Data for Injection Profile InterpretationProcesses · 2026
- Dual-Channel Thermal-Drift Modeling and Analytical Inverse Compensation for Tractor Hydraulic Output Power MeasurementAgriculture · 2026
- Improvement of Servo-Hydraulic Pressure Control Performance Using PSO-Optimized Fuzzy-PID ControlElectronics · 2026
- Design and Preliminary Characterization of an IoT-Enabled Multi-Sensor Monitoring and Control System for a Dual-Temperature Laboratory-Scale Biogas FermenterApplied Sciences · 2026