Temperature control model analysis of intelligent drilling fluid surface cooling equipment for high-temperature deep well working conditions
Keyou Guo, Shuai Wang, Zhenqi Meng, Zhongqing Lei, Dong Wang
Key points
From the paper's conclusion- The results showed that under the conditions of inlet temperature 160°C, drilling fluid flow rate 30 L/min, and cooling water flow rate 50 L/min, the optimised structure achieved an outlet temperature of 96.8°C, which was 15.8°C lower than the original structure.
Abstract
To address the problems of high drilling fluid return temperature, insufficient heat dissipation capacity of the surface circulation system, and significant outlet temperature fluctuations during deep and ultra-deep well drilling, this study designed intelligent drilling fluid surface cooling equipment and established a temperature control model and a CFD numerical simulation model. The equipment comprised a high-temperature drilling fluid inlet pipeline, a buffer tank, a plate heat exchanger, a cooling water circulation unit, a variable frequency pump, temperature/flow/pressure sensors, a PLC controller, and a data acquisition module. Based on the heat balance relationship between the drilling fluid and cooling water, models for heat exchange, logarithmic mean temperature difference, pressure drop, and pump power were established. Furthermore, an adaptive PID method was used to adjust the cooling water pump frequency to achieve closed-loop control of the outlet temperature. The numerical simulation used a three-dimensional steady-state incompressible turbulence model to analyse the internal temperature field and velocity field of the heat exchanger under 160°C inlet conditions, and the differences in heat exchange before and after structural optimisation. The physical test platform included a heating tank, a circulation pump, a plate heat exchanger, a cooling water tank, and a PLC control unit, which was used to verify the simulation results and temperature control response. The results showed that under the conditions of inlet temperature 160°C, drilling fluid flow rate 30 L/min, and cooling water flow rate 50 L/min, the optimised structure achieved an outlet temperature of 96.8°C, which was 15.8°C lower than the original structure. The overshoot of the adaptive PID was 3.1%, and the steady-state error was controlled within ±1.6°C, which was better than that of conventional PID. The maximum relative error between the simulated outlet temperature and the physical test results was 2.9%, indicating that the established model had good engineering applicability. The research results can provide a reference for the structural design, operating parameter optimisation, and intelligent temperature control strategy of surface cooling equipment for deep-well high-temperature drilling fluids.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Array-Based CTD Thermal Sensing for Low-Flow Downhole Applications with Dual-Mode Compensation.Sensors (Basel, Switzerland) · 2026
- Design and Electro-Thermal Optimization of Power Distribution Units for High-Temperature Industrial Fast Hole Drilling SystemsEnergies · 2026
- Modeling and Optimization of Transient Wellbore Temperature in Shale Oil Horizontal Wells Considering Variable Fluid Property and Multi-Source Heat GenerationProcesses · 2026
- Thermal-Fluid Simulation and Structure Optimization for Heat Dissipation of Submersible Pump MotorsProcesses · 2026
- Physics-Informed Neural Network-Based Inversion of Distributed Temperature Sensing Data for Injection Profile InterpretationProcesses · 2026
- Spatial temperature control system for reproducing typical operating conditions of turbine rotor systems.ISA transactions · 2026