Real-Time Laser Focus Tracking for Compressive Testing: Modular Rust Architecture with OPC UA and Web GUI for Laser Ultrasonics.
Konstantin Manuel Prabitz, Marco Schwarz, Bernhard Reitinger, Florian Rudinger, Alexander Walzl, Martin Stockinger
Chair of Metal Forming, Technical University of Leoben, Franz Josef-Straße 18, 8700 Leoben, Austria. · Research Center for Non Destructive Testing GmbH, Altenbergerstrasse 69, 4040 Linz, Austria.
Key points
From the paper's conclusion- This work addresses this engineering problem by providing a modular positioning-control system that couples a Gleeble 3800 thermo-mechanical simulator and a laser-ultrasonic measurement unit.
Abstract
Compression testing combined with laser ultrasonics enables non-destructive, in situ material characterisation during thermo-mechanical loading, but the shortening and radial expansion of the specimen displace the laser focal points during deformation and therefore require active repositioning of the laser-ultrasonic optics. This work addresses this engineering problem by providing a modular positioning-control system that couples a Gleeble 3800 thermo-mechanical simulator and a laser-ultrasonic measurement unit. The Gleeble provides two analogue shaft-position signals, which are digitised and used as real-time reference signals for stage-position control. The excitation and detection optics are mounted on motorised Zaber linear stages; two stages translate the optics along the compression direction, while a third perpendicular stage adjusts the detection focus to compensate radial specimen expansion and the limited depth of field of the detection optics. The control software was implemented in Rust and computes the stage target positions from the digitised Gleeble voltages output using user-configurable mathematical expressions. It further provides process-data access through an embedded OPC UA server and a browser-based graphical user interface through an integrated HTTP server. A custom ADC-based acquisition chain was introduced because the built-in ADC inputs of the Zaber controllers showed a significant noise level when used for the Gleeble shaft-position signals. Profiling showed that the control-loop runtime was dominated by ADC read/write operations; by reorganising acquisition into a parallel setup, the mean control-loop time was reduced from approximately 130 ms to approximately 27 ms. The resulting system provides an active, configurable, and retrofit-capable link between Gleeble compression testing and laser-ultrasonic measurement. It improves the temporal response available for laser-focus tracking on deforming specimens and provides a foundation for future quantitative validation of tracking error, positioning uncertainty, and LUS signal quality during real compression experiments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved laser Ultrasonics NDT through simultaneous quasi-monochromatic and pulsed Rayleigh waves generation.Ultrasonics · 2026
- A system for automated measurements of anisotropic elastic moduli using resonant ultrasound spectroscopy.The Review of scientific instruments · 2026
- Interaction mechanisms and grinding-force behavior in ultrasonic-assisted high-shear and low-pressure grinding of LN using ball-end body-armor-like abrasive toolsProceedings of the Institution of Mechanical Engineers Part B Journal of Engineering Manufacture · 2026
- Ultrasound real-time imaging of crack propagation during ultrasonic fatigue testsApplied Physics Letters · 2026
- Optimization of Ultrasonic Parameters and Model Development for Nondestructive CTE Measurement of LAS Ultra-Low-Expansion Glass Ceramics.Materials (Basel, Switzerland) · 2026
- Vibration-Based Measurement of Steel Wire Rope Fundamental Frequency Using an Optical Sensor: Mitigation of Mass-Loading Artifacts.Sensors (Basel, Switzerland) · 2026