RF Power, B1+rms, and SAR Variation with RF Coils, Conductive Metallic Implants, and Ionic Solutions at 1.5T and 3T.
David H Gultekin
Rockefeller Neuroscience Institute, Department of Neuroradiology, School of Medicine, West Virginia University, Morgantown, WV 26506, USA.
Key points
From the paper's conclusion- A method is developed to evaluate the variation in RF power, B1+rms, and SAR with RF coils, metallic implants, and ionic solutions using phantoms consisting of water (H2O) and sodium chloride (NaCl) with four ionic concentrations (0, 1, 2, 3%), four metallic wavelengths (0, λ/2, λ, 2λ), two RF coils (body, head), transmit/receive (Tx/Rx) combinations, and five RF pulse flip angles (30, 45, 60, 75,
Abstract
Currently, the time-averaged root-mean-square RF field (B1+rms) and specific absorption rate (SAR) are being evaluated to monitor and control RF-induced heating near conductive metallic implants, such as deep brain stimulation (DBS) leads, during MRI. However, experimental methods to assess the relationship between RF power, B1+rms, and SAR are lacking for RF coils, RF pulse sequences, metallic implants, and ionic solutions. A method is developed to evaluate the variation in RF power, B1+rms, and SAR with RF coils, metallic implants, and ionic solutions using phantoms consisting of water (H2O) and sodium chloride (NaCl) with four ionic concentrations (0, 1, 2, 3%), four metallic wavelengths (0, λ/2, λ, 2λ), two RF coils (body, head), transmit/receive (Tx/Rx) combinations, and five RF pulse flip angles (30, 45, 60, 75, 90 degrees) in two B0 fields (1.5T and 3T). The scanner-reported RF power and SAR varied with RF pulse sequences, RF coils, Tx/Rx, metallic implants, and ionic solutions, whereas B1+rms varied only with RF pulse sequences. The RF power, B1+rms, and SAR relationship depends on RF pulse sequences, RF coils, Tx/Rx, metallic implant wavelengths, and ionic concentrations. SAR (whole-body, head) scaled with RF power by absorption ratios (α) variable with experimental conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Head-only MRI of Deep Brain Stimulation devices at 0.5 T: Patient-derived approaches for estimating radiofrequency heating.NeuroImage · 2026
- Assessment of RF-Induced Heating of Stainless-Steel Sternal Wires at 7 T MRI.Magnetic resonance in medicine · 2026
- Reducing RF-Induced Heating of DBS in 3 T MRI Using Dual-Role Receive Arrays as Wireless Resonators: A Simulation Study.IEEE access : practical innovations, open solutions · 2026
- RF safety assessment of dental retainers for human head MRI array coils at 9.4 T.Magnetic resonance imaging · 2026
- RF-EMF response modeling of implantable medical electrodes under 1.5T and 3T MRI exposure using a lumped element model approach.Physics in medicine and biology · 2026
- Temperature-dependent nonlinear response in transient radio frequency heating of saline waterAIP Advances · 2026