Modeling the Variance of Passive SiPMs in the Nonlinear Regime.
Víctor Moya, Jaime Rosado
IPARCOS and Department of EMFTEL, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
Key points
From the paper's conclusion- These findings provide a practical framework for predicting photon-counting resolution and optimizing the operation of passive SiPMs over a wide dynamic range.
Abstract
Silicon photomultipliers (SiPMs) are widely used in high-energy physics, medical imaging, and other photon-counting applications. While their nonlinear response at high light intensities is well known, its impact on the statistical fluctuations of the detector output remains much less understood. In this work, we develop an analytical framework for the variance of the charge response of passive-quenching SiPMs in the two limiting cases of instantaneous light pulses and pulses much longer than the pixel recovery time. Based on these exact results, we propose a phenomenological model that describes the variance of the SiPM charge response for arbitrary pulse durations while accounting for pixel recovery and correlated noise. The resulting framework is then used to predict the photon-counting resolution over the full dynamic range of the detector. The model is validated through Monte Carlo simulations and experimental measurements performed with laser, LED, and scintillation light sources. The results show that the optimal photon-counting resolution is generally reached well beyond the onset of nonlinear response, since pixel saturation introduces sub-Poissonian fluctuations that partially compensate for the nonlinear compression of the SiPM response. These findings provide a practical framework for predicting photon-counting resolution and optimizing the operation of passive SiPMs over a wide dynamic range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Practical Calibration Method for Correcting Count-Rate Nonlinearity in Free-Running Silicon SPADsPhotonics · 2026
- Uncooled Photon‐Counting Detectors: From PMTs to CMOS‐Integrated and Emerging SPAD TechnologiesLaser & Photonics Reviews · 2026
- High-Performance SiPM Detection Module for Ultra-Fast Time-Resolved MeasurementsSensors · 2026
- Establishing Standards for Assessment and Reporting of SNSPD PerformancearXiv · 2026
- SiPM optical readout of a PICOSEC Micromegas precise timing detectorarXiv · 2026
- Enabling highly efficient infrared silicon photodetectors via disordered metasurfaces with upconversion nanoparticlesScience Advances · 2025