Dielectrophoretic Enrichment Coupled with Impedance Spectroscopy for Real-Time Bacterial Detection and Antibiotic Susceptibility Testing Using an Interdigitated Wave Electrode Array.
Zeeshan, Naeem Iqbal
School of Computing, Gachon University, Seongnam-si 13120, Gyeonggi-do, Republic of Korea. · Centre for Secure Information Technologies, Queen's University Belfast, Belfast BT3 9DT, UK.
Key points
From the paper's conclusion- Here, we report a real-time, label-free interdigitated wave electrode array (IWEA) that combines dielectrophoretic (DEP) enrichment with impedance spectroscopy for rapid bacterial detection and AST.
Abstract
Antimicrobial resistance (AMR), largely driven by the inappropriate and excessive use of antibiotics, requires rapid and reliable bacterial detection and antibiotic susceptibility testing (AST), as conventional culture-based methods remain time-intensive. Here, we report a real-time, label-free interdigitated wave electrode array (IWEA) that combines dielectrophoretic (DEP) enrichment with impedance spectroscopy for rapid bacterial detection and AST. The proposed IWEA was designed and optimized via COMSOL Multiphysics to enhance DEP-relevant electric-field strength, thereby improving DEP-assisted bacterial enrichment compared to conventional planar interdigitated electrodes. The platform enabled sensitive detection of both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) in 0.1× PBS across 10-105 CFU/mL within 30 min using DEP-assisted preconcentration (100 kHz, 10 Vpp), outperforming passive (non-DEP) operation (102-105 CFU/mL). For AST, bacterial responses to vancomycin, gentamicin, and ampicillin were monitored through impedance variations following DEP-based enrichment. Susceptible bacteria produced concentration-dependent reductions in ΔZ/Z0, whereas resistant bacteria showed similar responses to untreated controls. Quantitative assessment yielded CC50 values of 2.86 ± 0.22 µg/mL and 3.06 ± 0.20 µg/mL for vancomycin and gentamicin against S. aureus, and 4.59 ± 0.30 µg/mL for gentamicin against E. coli. Resistance profiles of S. aureus to ampicillin and E. coli to vancomycin and ampicillin were clearly distinguished. SEM imaging and disk diffusion assays independently validated the impedance-derived susceptibility results. Collectively, this IWEA platform offers a rapid, label-free, and quantitative approach for bacterial detection and AST, with strong potential for antimicrobial screening and point-of-care diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electric-Field-Assisted Enrichment and Electrochemical Detection of Gram-Positive Bacteria Using an FEM-Guided Interdigitated Electrode Biosensor.Biosensors · 2026
- Amperometric Typing for Rapid Monitoring of Antibiotic Resistance in Staphylococcus aureus.Biosensors · 2026
- Artificial Intelligence-Empowered Single-Cell Phenotyping for Rapid, Automated Pathogen Diagnostics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Transition-frequency dielectrophoresis for antibiotic detection through binding-induced interfacial charge modulation.Biosensors & bioelectronics · 2026
- Parallelised detection of bacteria viability using an electrode array and the Exeter Multiscope.Scientific reports · 2026
- Geometry-assisted dielectrophoretic localization on a CMOS sensor array for label-free detection of viable Escherichia coli.The Analyst · 2026