Parallelised detection of bacteria viability using an electrode array and the Exeter Multiscope.
Ka Kiu Lee, David Horsell, James Stratford, Magdalena Karlikowska, Salman Khattak, Tailise de-Souza-Guerreiro-Rodrigues, Junqing Jiang, Mike Shaw,
Department of Biosciences, University of Exeter, Exeter, UK. · Department of Physics and Astronomy, University of Exeter, Exeter, UK.
Key points
From the paper's conclusion- We demonstrate sufficient sensitivity to measure fluorescence changes after electrical stimulation in a bacterial monolayer.
Abstract
UNLABELLED: Antimicrobial resistance remains a global existential threat. Given that antimicrobial therapy commonly starts before pathogen identification, rapid and scalable methods capable of determining effective antimicrobial compounds are needed. In this paper, we demonstrate a 2 × 2 array of parallelised microscopes that uses low numerical aperture (NA = 0.25) detection optics and LED excitation to determine bacterial viability based on their fluorescence response to an electrical stimulus. Following a 2-hour incubation, the fluorescent viability readout requires less than one minute. We use K-means clustering to classify pixels in a time lapse sequence of widefield fluorescence images and extract changes seen within bacterial clusters. We demonstrate sufficient sensitivity to measure fluorescence changes after electrical stimulation in a bacterial monolayer. To capture these subtle fluorescence changes at high signal-to-background ratios, we place a limit on the minimum optical density of the bacterial sample. This novel approach is scalable to 96-well formats using a suitable consumable electrode array. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1038/s41598-026-66381-9.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Isolating viable bacteria from positive blood cultures: impedance cytometry analysis.Biomedical microdevices · 2026
- Dielectrophoretic Enrichment Coupled with Impedance Spectroscopy for Real-Time Bacterial Detection and Antibiotic Susceptibility Testing Using an Interdigitated Wave Electrode Array.Sensors (Basel, Switzerland) · 2026
- Large-Field Single-Cell Morphodynamic Scattering Imaging Enables Rapid, Heterogeneity-Resolved Phenotypic Antimicrobial Susceptibility Testing.ACS sensors · 2026
- Post-Competitive Interface Reprogramming for Amplified Multiplex Bacterial Fingerprinting in Biofluids.Analytical chemistry · 2026
- Biosensing Strategies for Bacterial Detection and Antimicrobial Susceptibility Testing: A Narrative Review.Biosensors · 2026
- A Viability Quantitative Fluorescence In Situ Hybridization (viqFISH) Strategy for Rapid Quantification of Membrane-Intact Escherichia coli in Urinary Tract InfectionsAnalytical Chemistry · 2026