Uncertainty Analysis and Metrological Validation of Raman Distributed Temperature Measurements in a Full-Scale Test Facility
Maxime Houvin, Rafik Moulouel, Pascal Borel, Didier Boldo
EDF Energy (United Kingdom)
Key points
From the paper's conclusion- The proposed approach provides a rigorous framework for the metrological qualification of Raman DTS systems and offers practical guidance for improving measurement reliability in distributed temperature monitoring applications.
Abstract
Raman Distributed Temperature Sensing (DTS) provides spatially distributed temperature measurements along optical fibers and is increasingly used for monitoring large-scale infrastructures and experimental facilities, enabling three-dimensional reconstruction of temperature fields. However, such measurements involve specific implementation constraints and may be affected by significant errors, with uncertainties influenced by factors such as calibration, environmental conditions, spatial resolution effects, and fiber positioning. Ensuring the metrological validity of Raman-based DTS measurements therefore requires a rigorous quantification of the associated measurement uncertainties. In this work, a complete uncertainty analysis of Raman-based DTS measurements is performed following the principles of the Guide to the Expression of Uncertainty in Measurement (GUM). A measurement model describing the relationship between Raman backscattered signals and temperature is established, and all relevant uncertainty sources are identified and quantified. The methodology is applied to a full-scale experimental facility equipped with a DTS interrogator and a dedicated calibration setup. Uncertainty propagation is performed using both first-order Taylor series expansion and Monte Carlo simulation, providing consistent results. The analysis shows that calibration uncertainty, spatial dispersion of the temperature field and fiber positioning within the reconstructed temperature field represent the dominant contributions to the combined uncertainty. The proposed approach provides a rigorous framework for the metrological qualification of Raman DTS systems and offers practical guidance for improving measurement reliability in distributed temperature monitoring applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Studies on attenuation corrected temperature demodulation in single ended Raman distributed temperature sensorsDiscover Sensors · 2026
- Feature calibration-enabled fine spatial resolution temperature demodulation with RDTS system.Optics express · 2026
- Resolving adjacent 20-cm hot spots over 2.5 km in Raman distributed optical fiber sensing via optimal chaotic segment correlation.Optics letters · 2026
- Distributed Temperature Sensing in the Spray-Cooled Shell of a 150-Ton DC Electric Arc Furnace Using Brillouin Optical Fiber TechnologyIEEE Transactions on Instrumentation and Measurement · 2026
- 70 km long-range Raman distributed optical fibre sensing through enhanced anti-distortion coding and waveform reconstructionNature Communications · 2025
- Raman Thermometry of Confined Gas Milli-Flows.Sensors (Basel, Switzerland) · 2026