Distributed Temperature Sensing in the Spray-Cooled Shell of a 150-Ton DC Electric Arc Furnace Using Brillouin Optical Fiber Technology
Farhan Mumtaz, Y. Mekala, Koustav Dey, Rony Kumer Saha, Ogbole Collins Inalegwu, M. Pullagura, Bohong Zhang, Muhammad Roman,
Missouri University of Science and Technology · Russian Medical Academy of Continuous Professional Education
Key points
From the paper's conclusion- This paper presents the deployment and validation of a Brillouin - distributed temperature sensing (DTS) system for real-time thermal monitoring of the spray-cooled upper shell of a 150-ton direct current Electric Arc Furnace (DC EAF) at Big River Steel Plant, Osceola, AR, USA.
Abstract
This paper presents the deployment and validation of a Brillouin - distributed temperature sensing (DTS) system for real-time thermal monitoring of the spray-cooled upper shell of a 150-ton direct current Electric Arc Furnace (DC EAF) at Big River Steel Plant, Osceola, AR, USA. A four-channel Brillouin DTS system from OZ Optics was employed, with one active channel instrumented using an in-house-fabricated Brillouin scattering-depressed single-mode optical fiber (SMF28e+). The 60 m optical fiber sensor was fabricated, with 20 m allocated for thermal measurement and 40 m used as lead-in fiber to isolate the interrogator from the furnace environment. The fiber was nested in stainless steel (SS) tubing and bonded to the hot-face surface of the shell using thermally conductive epoxy. The system captured transient thermal events including burner activation and process-induced heating over multiple furnace cycles. DTS-acquired data were validated against resistance temperature detector (RTD) measurements, confirming consistent thermal trends and system accuracy. Prior to the industrial deployment, several mock-up tests were conducted. Laboratory calibration demonstrated a linear Brillouin frequency shift with temperature, with a sensitivity of approximately 1.19 °C/MHz up to 515 °C and R2= 0.9988. Additional mock-up trials confirmed spatial resolution between 0.5 m and 1 m, with transmission and reflection spectra showing hotspot detection over sensing lengths up to 130 m. An averaging spatial step of 0.04 m was used, and acquisition sweep time was set to 1 min with a 10 MHz frequency step size and 10,000 averages. Monitoring the spray-cooled shell is critical in EAF operations due to its exposure to high thermal loads and susceptibility to localized overheating. Real-time hotspot detection and localization support proactive maintenance, reduce the risk of shell failure, and improve energy efficiency and operational safety. These findings underscore the potential of Brillouin - DTS systems to enable intelligent process control and predictive maintenance in next-generation steelmaking facilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Process Parameters on Thermal Response of an Oxy-Fuel Burner/Injector Panel in an Electric Arc Furnace via Fiber Optic SensorsMetallurgical and Materials Transactions B · 2026
- Comprehensive Literature Review: Optical Fiber Sensing Technologies for Advanced Low-Temperature and Cryogenic Applications.Sensors (Basel, Switzerland) · 2026
- Uncertainty Analysis and Metrological Validation of Raman Distributed Temperature Measurements in a Full-Scale Test FacilitySensors · 2026
- Full-Line Idler Fault Monitoring in Belt Conveyors via UWFBG-DAS and Characteristic Energy Feature Analysis.Sensors (Basel, Switzerland) · 2026
- Field performance and deployment challenges of a BOTDA-based distributed fibre optic inclinometer for microtunneling-induced ground deformation monitoringResults in Optics · 2026
- Vibrational temperature measurement of diatomic nitrogen using femtosecond/picosecond coherent anti-Stokes Raman scattering in the ONR-UTA arc-jet facilityExperiments in Fluids · 2026