Calibration of Low-Cost Sensors for PM10 and PM2.5 Based on Artificial Intelligence for Smart Cities
Ricardo Gómez, José Rodríguez, Roberto Ferro
Escuela Colombiana de Carreras Industriales · Universidad Distrital Francisco José de Caldas
Key points
From the paper's conclusion- This paper presents the results and conclusions derived from simultaneous PM10 and PM2.5 monitoring comparisons between LCS nodes and a T640X reference sensor.
Abstract
Exposure to Particulate Matter (PM) is linked to respiratory and cardiovascular diseases, certain types of cancer, and accounts for approximately seven million premature deaths globally. While governments and organizations have implemented various strategies for Air Quality (AQ) such as the deployment of Air Quality Monitoring Networks (AQMN), these networks often suffer from limited spatial coverage and involve high installation and maintenance costs. Consequently, the implementation of networks based on Low-Cost Sensors (LCS) has emerged as a viable alternative. Nevertheless, LCS systems have certain drawbacks, such as lower reading precision, which can be mitigated through specific calibration models and methods. This paper presents the results and conclusions derived from simultaneous PM10 and PM2.5 monitoring comparisons between LCS nodes and a T640X reference sensor. Additionally, Relative Humidity (RH), temperature, and absorption flow measurements were collected via an Automet meteorological station. The monitoring equipment was installed at the Faculty of Environment of the Universidad Distrital in Bogotá. The LCS calibration process began with data preprocessing, which involved filtering, segmentation, and the application of FastDTW. Subsequently, calibration was performed using a variety of models, including two statistical approaches, three Machine Learning algorithms, and one Deep Learning model. The findings highlight the critical importance of applying FastDTW during preprocessing and the necessity of incorporating RH, temperature, and absorption flow factors to enhance accuracy. Furthermore, the study concludes that Random Forest and XGBoost offered the highest performance among the methods evaluated. While satellites map city-wide patterns and MAX-DOAS enables hourly source attribution, our calibrated LCS network supplies continuous, street-scale data at low CAPEX/OPEX—forming a practical backbone for sustained micro-scale monitoring in Bogotá.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration of Low-Cost Particulate Matter Sensors for Exposure Assessment: A Critical Review.Current environmental health reports · 2026
- City-scale calibration of a low-cost PM2.5 network for regulatory-compliant air-quality assessmentPLOS Climate · 2026
- How Accurate Are Low-Cost Air Quality Sensors? A 10-Month Study of Three-Tier Comparison with Three Calibration Methods and Cross-Site Transferability.Sensors (Basel, Switzerland) · 2026
- A review of machine learning approaches for improving calibration and performance of low-cost air quality sensor networksSensor Review · 2026
- Software-Based Relative Humidity Compensation for Low-Cost Optical PM Sensors Using Machine Learning: A Case Study from Upper Silesia, Poland.Sensors (Basel, Switzerland) · 2026
- Evaluating and Calibrating Low-Cost Air Quality Sensors in Contrasting Aerosol RegimesAerosol and Air Quality Research · 2026