Comparative In Vitro Study on the Fracture Resistance of Titanium and Stainless Steel Orthodontic Miniscrews Subjected to Ageing
Andrea Scribante, Giuseppe Merlati, Maurizio Pascadopoli, Flavia Tomasoni, Davide Dirk Kramp, Giorgia Minghini, Maria Francesca Sfondrini
Key points
From the paper's conclusion- Titanium and stainless steel miniscrews of equal diameter did not differ at any single ageing time, although titanium showed lower values when ageing times were pooled and in regression analysis (p < 0.05).
Abstract
Background: Miniscrews are increasingly used in clinical practice to avoid side effects during teeth movements. The aim of the present study was to measure and compare the forces of orthogonal loads of stainless steel and titanium miniscrews with different diameters and subjected to thermal cycling. Methods: Ti-6Al-4V titanium and stainless steel orthodontic miniscrews from different manufacturers were tested. Miniscrews with diameters of 1.5 mm and 2.0 mm were evaluated. In total, 210 specimens were separated into seven groups according to manufacturer and diameter. For each group, 10 samples were tested as new, 10 specimens underwent thermocycling simulating 3 months in the oral cavity, and 10 samples underwent thermocycling simulating 6 months in the oral cavity. Specimens were positioned in an Instron Universal Testing Machine, and a shear load was applied at the neck of the miniscrew. Data were statistically analysed (p < 0.05). Results: Maximum load decreased with ageing, significantly so after six months in four titanium groups. Titanium and stainless steel miniscrews of equal diameter did not differ at any single ageing time, although titanium showed lower values when ageing times were pooled and in regression analysis (p < 0.05). Moreover, higher forces for 2.0 mm than 1.5 mm screws were necessary, both at 0.1 mm and 0.2 mm deflections and at maximum load. Conclusions: six months of thermocycling and two cycles of sterilisation seem to affect the mechanical properties of miniscrews.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermo-Mechanical Characterization of Innovative Side-Rounded Superelastic CuNiTi Orthodontic Wires.Journal of functional biomaterials · 2026
- Electrochemical and Surface Characterization of Nickel-Containing Orthodontic Archwires Under In Vitro and In Vivo Conditions.Dentistry journal · 2026
- In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles.Bioinformation · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- A Tensile Test-Based Investigation of Load Deflection Properties of Three Commercial Superelastic Nickel-Titanium Orthodontic Archwires: An In Vitro Study.Cureus · 2026
- Optimizing Miniscrew Stability: A Finite Element Study of Titanium Screw Insertion AnglesBiomimetics · 2025