From the paper's conclusion- Conclusions: Within the limitations of this in vitro study, 3D-printed denture base resins exhibited significantly greater early C. albicans adhesion than conventional PMMA.
Abstract
Objective: This study aimed to quantitatively assess early adhesion and qualitatively assess 48-h biofilm-like morphology of Candida albicans (C. albicans) on seven commercially available 3D-printed denture base resins compared with conventional heat-polymerized polymethyl methacrylate (PMMA). Materials and Methods: A total of 128 disc-shaped specimens (n = 16 per material) were fabricated using seven 3D-printed denture base resins and a PMMA control. Early C. albicans adhesion was quantitatively evaluated using the XTT assay at 490 nm after a fixed 1-h incubation. Qualitative analysis was performed using field-emission scanning electron microscopy (FESEM) at 1.5 h (early adhesion) and 48 h (biofilm-like morphology) on two representative printed resins (selected based on the lowest and highest XTT values among printed materials), PMMA, and a negative control. Results: XTT analysis demonstrated significantly higher early adhesion of C. albicans on all 3D-printed denture base resins compared with PMMA (p < 0.001). Among the printed resins, Shining 3D demonstrated significantly higher XTT values than all other printed resins except PRIZMA (p < 0.05). PRIZMA showed significantly higher adhesion than DETAX, NextDent, and ASIGA (p < 0.05). FESEM images at 1.5 h showed early yeast attachment on the two representative printed resins, while 48-h images showed visible surface colonization with yeast and hyphal forms on these representative printed resins compared with sparse yeast attachment on PMMA. Conclusions: Within the limitations of this in vitro study, 3D-printed denture base resins exhibited significantly greater early C. albicans adhesion than conventional PMMA. Among the printed resins, Shining 3D and PRIZMA showed the highest early adhesion. Qualitative SEM of two representative printed resins suggested visible surface colonization at 48 h. Because mature biofilm was not quantified and only two printed materials were imaged, these findings should be considered preliminary. Further studies are needed to confirm biofilm development and to determine the role of material chemistry, surface properties, and printing parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Candida albicans adhesion, biofilm formation and gene expression on conventional, milled and 3D-printed denture base materials: an in vitro study.BMC oral health · 2026
- Comparative Evaluation of Effect of Surface Roughness on Microbial Adhesion to Milled, 3D-Printed, and Conventional PMMA Denture Base Resin: An In Vitro Study.International journal of dentistry · 2026
- The effects of fabrication methods and build orientation on Candida albicans adhesion on 3D-printed and conventional denture resin: an in vitro comparative studyBMC Oral Health · 2025
- Evaluation of Candida albicans Colonization on Heat-Cured, Polyamide, and 3D-Printed Denture Base MaterialsInternational Journal of Drug Delivery Technology · 2026
- Effects of 3D-Printing Orientation and Materials Selection on Microbial Accumulation of Customized Healing Abutments: An In Vitro Comparative StudyDentistry Journal · 2026
- Effect of denture cleansing solutions on physical properties of 3D-printed and heat-polymerized denture base resinsBMC Oral Health · 2026