Effects of 3D-Printing Orientation and Materials Selection on Microbial Accumulation of Customized Healing Abutments: An In Vitro Comparative Study
Faisal E. Aljofi
Key points
From the paper's conclusion- Conclusions: Healing abutment material and manufacturing method, as well as 3D-printing orientation, were associated with differences in early microbial accumulation.
Abstract
Objectives: To evaluate the effect of different healing abutment materials and 3D-printing orientations on microbial accumulation by comparing commercially available titanium abutments with customized composite resin and 3D-printed healing abutments. Methods: Fifty healing abutments were allocated into five groups (n = 10): commercially available titanium (control), customized healing abutment resin composite CHA-Composite, and 3D-printed customized healing abutments printed in 0°, 45°, and 90° orientations (CHA-3DP-0, CHA-3DP-45, CHA-3DP-90). Following sterilization, specimens were incubated with standardized suspensions of S. aureus and C. albicans for 24 h. Adherent microorganisms were quantified by colony-forming unit (CFU) analysis, and representative specimens were examined using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA with Tukey’s post hoc test (α = 0.05). Results: Significant differences in microbial accumulation were observed among the experimental groups for both C. albicans and S. aureus (p < 0.001). The 3D-printed healing abutments at the 0° orientation demonstrated the lowest CFU counts for both microorganisms, significantly lower than all other groups (p < 0.001). In contrast, the 45° and particularly the 90° printing orientations exhibited significantly greater microbial accumulation. SEM findings corroborated the quantitative results, revealing reduced biofilm accumulation on 0°-3D-printed surfaces and more extensive biofilm formation on the 45° and 90° groups. Conclusions: Healing abutment material and manufacturing method, as well as 3D-printing orientation, were associated with differences in early microbial accumulation. Among the 3D-printed groups fabricated from the same resin, the 0° printing orientation showed the lowest S. aureus and C. albicans accumulation, suggesting that optimized printing orientation may reduce microbial accumulation. As the titanium, composite resin, and 3D-printed groups differed simultaneously in both material and fabrication method, these comparisons should be interpreted as reflecting specific material–manufacturing process combinations rather than an independent material effect. Further clinical and in vitro investigations are needed to confirm these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The effects of fabrication methods and build orientation on Candida albicans adhesion on 3D-printed and conventional denture resin: an in vitro comparative studyBMC Oral Health · 2025
- Candida albicans adhesion, biofilm formation and gene expression on conventional, milled and 3D-printed denture base materials: an in vitro study.BMC oral health · 2026
- Candida albicans Adhesion on 3D-Printed Denture Base Materials: An Exploratory Comparative In Vitro StudyProsthesis · 2026
- Biofilm-Associated Viable Cell Recovery of Streptococcus salivarius K12 and M18 Probiotic Strains on Conventional, CAD/CAM-Milled, and 3D-Printed Denture Base Materials: An In Vitro Microbiological Study.Microorganisms · 2026
- Comparative Evaluation of Effect of Surface Roughness on Microbial Adhesion to Milled, 3D-Printed, and Conventional PMMA Denture Base Resin: An In Vitro Study.International journal of dentistry · 2026
- Evaluation of Candida albicans Colonization on Heat-Cured, Polyamide, and 3D-Printed Denture Base MaterialsInternational Journal of Drug Delivery Technology · 2026