ProsthesisOpen accessFinite element method

Finite Element Analysis of Collared Hip Prosthesis Cross-Sections Under Dynamic Loading and Wear Conditions for Durable Orthopedic Implant Design

Chethan K N, John Valerian Corda, Laxmikant G. Keni, M. Kalayarasan, Jonathan Reginald, Sudhir Jain Prathik

Manipal Academy of Higher Education · PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH

Key points

From the paper's conclusion
  • This study investigates the performance of novel collared hip implant designs under walking conditions, focusing on geometric profiles and two common stem materials: Ti-6Al-4V and CoCr alloy.

Abstract

Background/Objective: Traditional hip implant evaluations often overlook patient-specific dynamic loadings. This study investigates the performance of novel collared hip implant designs under walking conditions, focusing on geometric profiles and two common stem materials: Ti-6Al-4V and CoCr alloy. Methods: Patient-specific dynamic forces were applied using commercial finite element analysis, adhering to ISO and ASTM standards. Four cross-sectional profiles—circular, elliptical, oval, and trapezoidal—were initially evaluated for induced stresses and displacements. Subsequently, wear characteristics at implant junctions were analyzed, comparing CoCr (MC 1) and Ti-6Al-4V (MC 2) stems. The study also assessed the impact of using Ultra-High Molecular Weight Polyethylene (UHMWPE) acetabular cups. Results: The elliptical (CS 2) cross-sectional profile demonstrated superior performance. Junction analysis revealed that the CoCr stem (MC 1) exhibited a stem-to-head sliding distance four times higher and contact pressure 5.5 times higher than the Ti-6Al-4V stem (MC 2). Specifically, MC 1 showed 82% higher contact pressure and 89% greater sliding distance at the stem–head junction compared to MC 2. Additionally, utilizing UHMWPE cups effectively eliminated squeaking sounds attributed to CoCr cups due to superior wear resistance. Conclusions: The combination of an elliptical (CS 2) cross-sectional profile with a Ti-6Al-4V stem and UHMWPE acetabular cup offers optimal performance. This configuration significantly reduces wear and contact pressure, suggesting enhanced functionality and durability for hip implants under dynamic loading conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Finite Element Analysis of Collared Hip Prosthesis Cross-Sections Under Dynamic Loading and Wear Conditions for Durable Orthopedic Implant Design — Science Skim