Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous Control
Yunpeng Huang, Nan Wang, Dapeng Zhang, Zhenyu Liu, Yuanyi Zhang, Yongjun Zhou, Xueshen Zhao, Yuqing Qu
Key points
From the paper's conclusion- To investigate the reverse frequency overshoot and transient oscillations that may arise in an islanded hydro-storage microgrid using conventional P–ω virtual synchronous control under specific parameter settings, this paper analyzes the active-power–frequency dynamic external characteristics of the microgrid under P–ω2 virtual synchronous control.
Abstract
To investigate the reverse frequency overshoot and transient oscillations that may arise in an islanded hydro-storage microgrid using conventional P–ω virtual synchronous control under specific parameter settings, this paper analyzes the active-power–frequency dynamic external characteristics of the microgrid under P–ω2 virtual synchronous control. An active-power–frequency dynamic model coupling the physical inertia of the hydro-turbine synchronous generator and the virtual inertia of the grid-forming energy-storage converter is established. The power–frequency regulation characteristics of P–ω and P–ω2 control are compared, and the effects of virtual inertia and virtual damping on the active-power–frequency dynamic external characteristics are analyzed. A joint inertia–damping parameterization is then formulated, and the effects of parameter scaling and load-disturbance magnitude on the active-power–frequency dynamic external characteristics of the microgrid are evaluated using the maximum frequency deviation, rate of change of frequency, and dynamic recovery time. PSCAD/EMTDC simulation results show that, compared with conventional P–ω control, P–ω2 control mitigates reverse frequency overshoot and transient oscillations during the recovery process. The inertia–damping parameter combination and load-disturbance magnitude significantly affect the system frequency dynamics, thereby validating the established model and the corresponding external-characteristic analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on Fractional-Order Virtual Synchronous Generator Control with Fuzzy Adaptive Inertia and Damping RegulationEngineering Research Express · 2026
- Stabilizing an AC-DC Micro-Grid Powered by Residual-Pressure Energy with the Additional Damping Controller of the ConverterEnergies · 2026
- Parameter Tuning and Adaptive Strategy for Grid-Forming Energy Storage Systems Under Multi-Disturbance ConditionsEnergies · 2025
- Frequency Regulation Performance of a Wind–Energy Storage Hybrid System During Turbine Shutdown Due to Extreme WindProcesses · 2025
- Energy Storage Multi-Stage Dynamic Frequency Modulation Control Strategy Based on Inertia–Damping Coordination TuningEnergies · 2026
- Virtual inertia control for enhanced frequency stability in islanded microgrids: A multistage PID and modified golf optimization approachNext Energy · 2026