Parameter Tuning and Adaptive Strategy for Grid-Forming Energy Storage Systems Under Multi-Disturbance Conditions
Shoudong Xu, Xinze Xi, Hengchu Shi, Junzhao Cheng, Hengrui Ma
China Southern Power Grid (China) · Power Grid Corporation (India)
Key points
From the paper's conclusion- To ensure the dynamic stability of the grid-forming energy storage system, this paper proposes a virtual synchronous machine (VSM) control parameter tuning and adaptive switching strategy.
Abstract
In power systems with a high penetration of renewable energy, integrating battery energy storage systems can enhance frequency regulation capabilities. However, in “islanded” operation mode, the lack of large grid interconnection support may cause significant frequency fluctuations or even instability when the system faces fault disturbances. To ensure the dynamic stability of the grid-forming energy storage system, this paper proposes a virtual synchronous machine (VSM) control parameter tuning and adaptive switching strategy. A control model is developed, which incorporates virtual inertia, damping, droop control, and transient virtual impedance. An optimization model for control parameter tuning is established for two typical disturbances: generator disconnection and three-phase symmetrical short-circuit fault. Additionally, a control parameter adaptive switching mechanism is designed based on voltage threshold and recovery time criteria. The application of this method to a simulation of an islanded power system demonstrates that high damping (e.g., greater than 15 pu) is suitable for generator disconnection disturbances, while a combination of low inertia (0.1 s) and high damping (50 pu) is appropriate for three-phase short-circuit disturbances. The control parameter tuning for three independent and aggregated scenarios successfully achieves effective frequency support. The adaptive switching criteria are set with a voltage threshold of 0.4 pu and a recovery time of 2 s, ensuring that the system frequency recovers within the specified range (48.5–51.5 Hz) within 1 s under short-circuit disturbance. The proposed method shows great potential for improving the operational stability of grid-forming energy storage systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy Storage Multi-Stage Dynamic Frequency Modulation Control Strategy Based on Inertia–Damping Coordination TuningEnergies · 2026
- Analysis of the External Characteristics of a Hydro-Storage Microgrid Based on P–ω2 Virtual Synchronous ControlProcesses · 2026
- Energy-Aware Finite-Horizon MPC Coordination of Adaptive VSG Inertia and BESS Control for Transient-Stability Enhancement in Renewable-Dominated Low-Inertia Hybrid Microgrids.Sensors (Basel, Switzerland) · 2026
- Modeling of Grid-Connected PV–Storage System with Frequency Support Capability Under Multi-Mode Control StrategyEnergies · 2026
- A Grid-Forming Battery Energy System with Mode-Adaptive Virtual Inductance ControlBatteries · 2026
- Multi-timescale energy-aware grid-forming control with self-tuning virtual inductance for battery lifetime enhancementScientific Reports · 2026