Effects of Cleaning Processes and Thin-Film Parameters on the Long-Term Stability of an Acid-Corrosion-Resistant Flexible Three-in-One Microsensor
Chi-Yuan Lee, Guo-Bin Jung, Jyun-Wei Yu, Ming-Chun Wu, Kuan-Ting Lai, Chien-Hsiang Hsu, Cheng-I Lin
Key points
From the paper's conclusion- These results identify a promising fabrication configuration and demonstrate embedded multiparameter sensing under the investigated conditions, providing a basis for further reliability evaluation.
Abstract
A flexible three-in-one microsensor integrating voltage, current, and temperature sensing functions was developed on a polyimide substrate using micro-electro-mechanical systems technology. Sea Energe cleaning agent B, an aqueous formulation containing mineral-derived ionic components and additives, was evaluated as an alternative to conventional organic-solvent cleaning for polyimide substrate pretreatment. The effects of substrate cleaning, Au electrode thickness, and protective-layer thickness were examined using a Taguchi L4 orthogonal array. Four microsensors, with one device per configuration, were calibrated before and after thermal aging at 150 °C for 200 h. Separate immersion tests were conducted in deionized water and undiluted commercial sulfuric acid with a supplier-specified concentration of 96%. Baseline resistance shifts ranged from 0.254% to 0.797%, and mean absolute temperature deviations ranged from 1.12 to 3.20 °C. Sensor 1, combining conventional organic-solvent cleaning, a 0.3 μm Au electrode, and a 25 μm protective layer, exhibited the smallest changes. Descriptive factor-level comparisons associated electrode thickness with the largest differences in both aging metrics. Separate microsensors prepared using the two cleaning processes provided continuous local voltage, current, and temperature signals during 20 h of proton exchange membrane water electrolyzer operation. These results identify a promising fabrication configuration and demonstrate embedded multiparameter sensing under the investigated conditions, providing a basis for further reliability evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Self-Cleanable Microelectromechanical Systems pH Sensor Based on Three-Dimensional Truncated Pyramid Microstructured IrOx/TiO Composite Electrodes.ACS sensors · 2026
- Evaluation of filter substrates for concurrent optical photothermal infrared and Raman spectroscopy in microplastic analysis.Analytical and bioanalytical chemistry · 2026
- All-3D Printed Microelectrodes.Analytical chemistry · 2026
- Universal Parafilm®-Mediated Thermal Bonding for Gold Leaf Electrode Patterning and Microfluidic Assembly on Diverse Substrates.Micromachines · 2026
- Effects of substrate roughness on the fabrication and properties of Ag/AgCl pseudo-reference electrodes for solid-state electrochemical sensors.Frontiers in chemistry · 2026
- Fabrication of photoresist SU-8 pyrolyzed carbon electrodes and their integration in a microfluidic hematocrit detection system.Biomedical microdevices · 2026