Investigation on the Anti-Freezing and the Heat Preservation Characteristics for a Semi-Underground Water Storage Tank
Dakun Xu, Hao Wang, Zhen Tian, Xueting Ren, Huishu Li, Xiaoqian Liu, Wenke Zhang
Key points
From the paper's conclusion- The results indicate that significant heat dissipation occurs through the top and sidewalls of the tank if there is no insulation, leading to a continuous decline in water temperature and a risk of localized freezing.
Abstract
In cold regions, semi-underground water storage tanks (WSTs) have problems such as low water temperatures and local freezing during winter operation. For its anti-freezing and heat preservation, relevant theoretical analysis and technical exploration are urgently needed. The study employs numerical simulation to investigate the effects of different thermal insulation measures on the anti-freezing performance of WSTs. Firstly, the numerical models were established to analyze the temperature distribution characteristics of the water body under low-temperature ambient conditions. Secondly, an experimental platform was also constructed, and the numerical models were validated through experimental measurements. On this basis, a 1200 h transient numerical simulation was conducted for a large-scale semi-underground WST. Finally, comparative analyses were performed on temperature variations between the uninsulated and variably insulated cases, and insulation layers of varying thicknesses and materials. The results indicate that significant heat dissipation occurs through the top and sidewalls of the tank if there is no insulation, leading to a continuous decline in water temperature and a risk of localized freezing. As the insulation thickness increases, the internal temperature of the tank gradually rises. However, when the thickness reaches 150 mm, further increases yield only marginal improvements of thermal insulation performance. Further comparison between 150 mm rock wool and 150 mm polyurethane insulation shows that the polyurethane provides better temperature retention. Therefore, the addition of a 150 mm of thick polyurethane insulation layer is identified as the optimal scheme. Lastly, by combining numerical simulation with experimental methods, the studies established a dynamic temperature field analysis for semi-underground WSTs, which can provide a theoretical basis and technical guidance for the anti-freezing and thermal insulation design of WSTs in cold regions, and therefore promote the popularization and application of WSTs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental and numerical study of a large-scale water pit thermal energy storage: Quantifying the impact of progressive lid insulation degradationJournal of Energy Storage · 2025
- Heat transfer analysis of thawing behavior in artificially frozen subway cross passage under seepage conditionsTunnelling and Underground Space Technology · 2026
- A hydronic closed-loop coupled with underground water tank for cooling photovoltaic panels in hot and arid climatesApplied Thermal Engineering · 2026
- Assessment and Improvement Strategies for the Winter Indoor Thermal Environment of Temporary Construction-Site Buildings in Cold RegionsBuildings · 2026
- Overwintering stability assessment of deep foundation pits in cold regions considering thermo-hydro-mechanicalJournal of Physics: Conference Series · 2026
- Influence of the West Wall Dynamic Thermal Behavior Under Specific Climate Conditions on the Electric Load of a Cold Storage FacilityEnergies · 2026