PGNN-Based Harmonic Source Localization in Distribution Networks
Pengchao Lei, Sijia Liu, Ziyi Yuan
Key points
From the paper's conclusion- These results demonstrate the effectiveness of integrating BIBC-based physical priors with data-driven learning for joint harmonic source localization and nodal harmonic injection-current estimation on the two simulated radial distribution systems considered in this study.
Abstract
Accurate localization and quantification of multiple harmonic sources from limited synchronized measurements remain challenging in distribution networks. To address measurement noise, limited phasor measurement unit (PMU) deployment, and insufficient physical consistency in purely data-driven models, this paper proposes a physics-guided neural network (PGNN) incorporating bus-injection-to-branch-current (BIBC) constraints. The method combines the branch harmonic-current phasors available under the PMU observability configuration with a minimum-norm nodal-current prior obtained using the pseudoinverse of the corresponding observable BIBC submatrix. A shared convolutional feature extractor with classification and regression heads jointly estimates source locations and nodal harmonic injection currents. A BIBC-based branch-current consistency term penalizes discrepancies between reconstructed and available branch currents. Simulations on the modified IEEE 13-bus and modified IEEE 33-bus systems demonstrate that, under complete branch-current observability and a nominal noise level of 5%, PGNN achieves higher exact-match accuracy (EM) and micro-averaged F1-scores than the convolutional neural network (CNN), fully connected neural network (FCNN), and graph convolutional network (GCN) baselines for the 3rd, 5th, 7th, and 11th harmonics. Under these conditions, PGNN also yields lower current-magnitude percentage errors and phase-angle errors relative to the BIBC-derived reference. Further tests using third-harmonic data from the modified IEEE 33-bus system characterize PGNN performance under 0–20% noise, reduced training-set sizes, and selected reduced-PMU configurations. These results demonstrate the effectiveness of integrating BIBC-based physical priors with data-driven learning for joint harmonic source localization and nodal harmonic injection-current estimation on the two simulated radial distribution systems considered in this study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physics-grounded sequence-domain graph learning for adaptive fault location in IBR-dominated offshore wind farm transmission networksDiscover Artificial Intelligence · 2026
- IP-GNO: An Inductive Physics-Informed Graph Neural Operator for Automated Distribution System State EstimationarXiv · 2026
- Research on Fault Diagnosis and Classification of High‐Voltage Transmission Lines Based on an Improved CNN ModelInternational Transactions on Electrical Energy Systems · 2026
- Interval Harmonic State Estimation of Three-Phase Asymmetric Distribution Network by Integrating Multi-Source DataProtection and Control of Modern Power Systems · 2026
- Voltage sag and short interruption edge-side tracing model based on a spiking spatiotemporal causal graph convolutional networkAIP Advances · 2026
- A Dual Sharing Strategy in Multi-Task Learning for Harmonic Signal DecompositionSymmetry · 2026