Techno-Economic Optimization of a Hybrid Renewable Energy System with Seawater-Based Pumped Hydro, Hydrogen, and Battery Storage for a Coastal Hotel
Tuba Tezer
Technical and Vocational University
Key points
From the paper's conclusion- Overall, these results confirm the techno-economic and environmental benefits of combining seawater-based PHS with optional hydrogen and battery storage for sustainable hotel-scale applications.
Abstract
This study presents the design and techno-economic optimization of a hybrid renewable energy system (HRES) for a coastal hotel in Manavgat, Türkiye. The system integrates photovoltaic (PV) panels, wind turbines (WT), pumped hydro storage (PHS), hydrogen storage (electrolyzer, tank, and fuel cell), batteries, a fuel cell-based combined heat and power (CHP) unit, and a boiler to meet both electrical and thermal demands. Within this broader optimization framework, six optimal configurations emerged, representing grid-connected and standalone operation modes. Optimization was performed in HOMER Pro to minimize net present cost (NPC) under strict reliability (0% unmet load) and renewable energy fraction (REF > 75%) constraints. The grid-connected PHS–PV–WT configuration achieved the lowest NPC ($1.33 million) and COE ($0.153/kWh), with a renewable fraction of ~96% and limited excess generation (~21%). Off-grid PHS-based and PHS–hydrogen configurations showed competitive performance with slightly higher costs. Hydrogen integration additionally provides complementary storage pathways, coordinated operation, waste heat utilization, and redundancy under component unavailability. Battery-only systems without PHS or hydrogen storage resulted in 37–39% higher capital costs and ~53% higher COE, confirming the economic advantage of long-duration PHS. Sensitivity analyses indicate that real discount rate variations notably affect NPC and COE, particularly for battery-only systems. Component cost sensitivity highlights PV and WT as dominant cost drivers, while PHS stabilizes system economics and the hydrogen subsystem contributes minimally due to its small scale. Overall, these results confirm the techno-economic and environmental benefits of combining seawater-based PHS with optional hydrogen and battery storage for sustainable hotel-scale applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integration of solar, wind, and wave energy for sustainable hotel operation in coastal regions: optimization of a building with hydrogen-supported hybrid renewable energy systemEnergy Strategy Reviews · 2026
- Techno-economic and reliability analysis of a grid connected hybrid microgrid with hydrogen storage for sustainable rural electrificationDiscover Sustainability · 2026
- Multi-objective techno-economic and environmental optimization of hydrogen-based hybrid renewable energy system using osprey optimization algorithmScientific Reports · 2026
- Multi-objective optimization of hybrid renewable energy systems for sustainable resource management and emission mitigation in climate-sensitive regionsEnergy Conversion and Management X · 2026
- Least-Cost Sizing and Multi-Criteria Assessment of Hybrid Solar–Wind–Hydrogen Systems Under Climate–Resource Sensitivity ScenariosEng · 2026
- Optimal design and energy management of a hybrid PV-Wind system with hydrogen and gravity energy storage: An off-grid sustainable alternative for coal power in MoroccoRenewable energy focus · 2025