Experimental and Numerical Investigation of Orthotropic CFR-PEEK and Ti-6Al-4V Osteosynthesis Plates Using a Multiscale Finite Element Modeling Approach.
Madina Isametova, Sholpan Kurmanova, Nurgul Seiitkazy, Yeszhan Ilyassov, Denis Tkachenko, Arailym Tursynbayeva
Institute of Energy and Mechanical Engineering, Department of Mechanical Engineering, Satbayev University, Almaty 050000, Kazakhstan. · Institute of Architecture and Civil Engineering, Department of Civil Engineering and Building Materials, Satbayev University, Almaty 050000, Kazakhstan.
Key points
From the paper's conclusion- The investigation employed a multiscale approach integrating micromechanical modeling using the Mori–Tanaka homogenization method in Digimat-MF, experimental mechanical testing of FDM-fabricated CFR-PEEK specimens containing 10 wt.% carbon fibers, and finite element analysis of osteosynthesis plates made of CFR-PEEK with 10 and 30 wt.% carbon fibers and Ti-6Al-4V using MSC Patran/Marc.
Abstract
The application of carbon fiber-reinforced polyetheretherketone (CFR-PEEK) composites in osteosynthesis implants represents a promising approach to mitigating the stress-shielding effect associated with the high stiffness of conventional metallic implants. This study aimed to experimentally and numerically evaluate the effects of short carbon fiber content and the orthotropic mechanical properties of CFR-PEEK on the structural strength of osteosynthesis plates and load distribution within the bone-plate system. The investigation employed a multiscale approach integrating micromechanical modeling using the Mori-Tanaka homogenization method in Digimat-MF, experimental mechanical testing of FDM-fabricated CFR-PEEK specimens containing 10 wt.% carbon fibers, and finite element analysis of osteosynthesis plates made of CFR-PEEK with 10 and 30 wt.% carbon fibers and Ti-6Al-4V using MSC Patran/Marc. CFR-PEEK 30% specimens were neither fabricated nor experimentally tested. Their mechanical properties were predicted using Digimat-MF by applying correction factors derived from experimental data obtained for CFR-PEEK 10%. The results demonstrated that increasing the carbon fiber content from 10 to 30 wt.% enhanced the longitudinal elastic modulus. Experimental testing of CFR-PEEK containing 10 wt.% carbon fibers revealed an elastic modulus ranging from 1.76 to 3.10 GPa and a tensile strength of 47-54 MPa. Following process-related adjustments to the material properties, finite element simulations of the bone-plate system were performed under an axial load of 50 N. The calculated load shielding indices were 94.3% for Ti-6Al-4V, 28.6% for CFR-PEEK 10%, and 54.3% for CFR-PEEK 30%, indicating the potential of composite implants to improve mechanical load transfer to the surrounding bone tissue. A preliminary strength assessment based on the three-dimensional Tsai-Hill failure criterion yielded failure indices of 15.577 and 1.112 for CFR-PEEK 10% and CFR-PEEK 30%, respectively, under the assumed material strength parameters. Critical stress concentrations were predominantly localized around the fixation holes. These findings highlight the trade-off between reducing stress shielding and ensuring the structural integrity of composite osteosynthesis plates. The results further emphasize the need for localized optimization of fixation regions to improve mechanical reliability without increasing the overall implant thickness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical evaluation of carbon fiber-reinforced polyether ether ketone versus titanium plates for fixation of high tibial osteotomy.Clinical biomechanics (Bristol, Avon) · 2026
- Analysis of the postoperative mechanical properties of PEEK bone plates in a distal femoral fracture model.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Additive Manufacturing of Poly(Ether‐Ketone‐Ketone)/Short Carbon Fibers Composites and Thermophysical PropertiesPolymer Composites · 2025
- PEEK plates for the fixation of mandibular condylar base fractures: a finite element analysis comparison of single and double plate configurations with titanium and resorbable systems.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesisFrontiers in Dental Medicine · 2026
- Surface‐Modified Carbon Fiber Reinforced MC PA6 Composites With Enhanced Mechanical and Tribological PropertiesPolymer Composites · 2026