Physicochemical and Mechanical Characterization of Silk and PGLA Dental Sutures Following Humic-Acid-Containing Surface Treatment.
Aysun Akpınar, Halil Çelik, Mehmet Kılınç, Zeynep Ceren Çelik, Ali Merdji, Sandipan Roy
Department of Periodontology, Faculty of Dentistry, Bursa Uludag University, Bursa 16120, Turkey. · Department of Oral and Dental Health, Vocational School of HealthCare Services, Istinye University, Istanbul 34396, Turkey.
Key points
From the paper's conclusion- This study was conducted to characterize the changes associated with a humic-acid-containing alginate coating applied to silk and poly(glycolide-co-lactide) (PGLA) sutures in two sizes (3-0 and 4-0).
Abstract
Surface coating may influence the physicochemical and mechanical properties of surgical sutures. This study was conducted to characterize the changes associated with a humic-acid-containing alginate coating applied to silk and poly(glycolide-co-lactide) (PGLA) sutures in two sizes (3-0 and 4-0). Untreated sutures served as controls. Surface-related spectral changes were examined using Fourier-transform infrared (FTIR) spectroscopy, while mechanical properties were evaluated via tensile testing in accordance with EN ISO 2062. Maximum tensile force and elongation at break were recorded. FTIR analysis revealed changes in the intensity and breadth of selected absorption bands, particularly those associated with O-H and C=O groups, after the coating was applied. These findings indicated treatment-associated spectral changes but did not independently confirm humic acid incorporation or coating stability. The maximum tensile force was lower in treated silk sutures than in untreated controls for both size 3-0 (22.6 ± 3.68 N vs. 17.8 ± 1.35 N; p = 0.140) and size 4-0 (12.8 ± 1.21 N vs. 10.6 ± 2.56 N; p = 0.276), although neither difference was statistically significant. For PGLA sutures, no statistically significant difference was observed for size 3-0 (27.7 ± 2.80 N vs. 27.6 ± 2.56 N; p = 0.966). In contrast, the size 4-0 PGLA sutures exhibited a higher maximum tensile force following treatment (14.2 ± 1.85 N vs. 21.1 ± 2.45 N; p = 0.021). Elongation at break increased in the treated size 3-0 silk sutures (16.0 ± 0.91% vs. 20.3 ± 1.10%; p = 0.007) and decreased in the treated size 4-0 silk sutures (19.3 ± 1.26% vs. 14.8 ± 1.75%; p = 0.027). No statistically significant differences in elongation were found for size 3-0 PGLA (32.1 ± 1.16% vs. 28.4 ± 2.21%; p = 0.082) or size 4-0 PGLA sutures (31.4 ± 1.88% vs. 30.8 ± 1.24%; p = 0.672). These preliminary findings indicate that the humic-acid-containing alginate coating procedure was associated with spectral changes and different mechanical responses in silk and PGLA sutures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical and Gravimetric Response of Surgical Suture Biomaterials to Commercial Mouthrinses During Static In Vitro Exposure.Bioengineering (Basel, Switzerland) · 2026
- Structure-Dynamics-Property Relationships in Silk Fibroin Films Probed via Solid-State NMRACS Omega · 2026
- Process-Driven Modulation of Structure and Cytocompatibility in Electrospun Silk Fibroin Membranes through Controlled Degumming.ACS omega · 2026
- A Multi‐Analytical Investigation of Lacquered Gauze From a Late Tang Tomb: Weaving Structure, Material Composition, and Technological ImplicationsArchaeometry · 2026
- Investigation into the Mechanical Properties of Swimming-Goggle Gaskets After Prolonged Water Conditioning.Materials (Basel, Switzerland) · 2026
- Ramie Elementary Fiber-Reinforced Chitosan Composite Films: Mechanical Properties and Structural Characterization.Polymers · 2026