Deformation-Aware Monte Carlo Assessment of a Bi2O3/Thermoplastic Polyurethane Shielding Surrogate Under Tensile Strain and Local Thickness Loss.
Ahmed Alharbi, Zeyad Alawaji
Department of Physics, College of Science, Qassim University, Buraydah 51452, Saudi Arabia. · Department of Radiologic Technology, College of Applied Medical Sciences, Qassim University, Buraydah 51452, Saudi Arabia.
Key points
From the paper's conclusion- Beer-Lambert attenuation accounts for the primary response to prescribed uniform thinning; the Monte Carlo framework additionally resolves polychromatic scatter, spectral changes, and localized dose enhancement.
Abstract
Flexible shielding polymers may undergo geometric thinning during tensile use or localized damage, but flat-sheet attenuation measurements cannot resolve the resulting spatial loss of protection. A radiation-transport surrogate comprising 60 wt% thermoplastic polyurethane and 40 wt% Bi2O3 (modeled density, 1.835 g cm-3) was investigated using prescribed deformation, Geant4, PHITS, Phy-X/XCOM, and 60-120 kVp SpekPy spectra. This is a computational transport model, not a mechanically or experimentally validated formulation. Geant4 mass attenuation coefficients were verified against Phy-X at six energies (30-100 keV) and against XCOM at 90, 91, 92, and 95 keV across the Bi K-edge. Constant-volume uniform strain of 50% raised whole-field transmission by 14.8-32.8%; an illustrative transverse-response sensitivity quantified the dependence of thickness and attenuation on the prescribed kinematics. At 50% local thinning, whole-field transmission increased by only 5.66-15.0%, whereas 5-million-history event-based ROI scoring gave dose enhancement factors of 2.435±0.106, 1.823±0.064, 1.508±0.048, and 1.395±0.042 at 60, 80, 100, and 120 kVp, respectively. Additional 60 kVp calculations varied the defect dimensions, ROI size, and detector position, revealing the influence of spatial averaging. Beer-Lambert attenuation accounts for the primary response to prescribed uniform thinning; the Monte Carlo framework additionally resolves polychromatic scatter, spectral changes, and localized dose enhancement. These numerical results characterize idealized geometric perturbations and should not be interpreted as measurements of real garment durability or clinical dose.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Nano-Bismuth-Silicone Polymer Composite as Shielding for X-Rays in Extreme-Environment Applications: Experimental and Simulation Studies.Nanomaterials (Basel, Switzerland) · 2026
- First-principles simulation of radiation shielding performance in TaS2–HDPE composites using Geant4Scientific Reports · 2026
- Environmental and Non‐Toxic New Radiation Shielding Materials Alternative to Lead: Preparation, Evaluation of Their Effectiveness on Gamma Attenuation Coefficients, and Investigation of Thermal PropertiesPolymers for Advanced Technologies · 2026
- Radiation Attenuation Performance of Highly Filled Tungsten/TPU Composites via Anchor–Chain Dispersant-Based Interfacial DesignPolymers · 2026
- Design and shielding effectiveness of adjustable modular medical radiation shelter.Radiation protection dosimetry · 2026
- Monte Carlo-based correction of scattering effects in low-energy mass attenuation experimental measurements of 3D-Printed polymers.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026