Effects of Sterilization Processes with Hydrogen Peroxide and Ethylene Oxide on Commercial 3D-Printed PLA, PLA-FC, and PETG by Fused Deposition Modeling
Mauricio Fuentes, Homero Cadena, Abel Remache, Omar Flor-Unda, Santiago Sarria, J.A. Delgado, Pablo M. Bonilla-Valladares, Santiago Ferrándiz Bou
Central University of Ecuador · Universidad de Las Américas
Key points
From the paper's conclusion- Overall, HP and EO sterilization can be safely applied to additively manufactured medical components based on these polymers, provided that the structures are not subjected to high mechanical loads and do not require strict dimensional tolerances.
Abstract
Polymers such as PLA, PLA reinforced with carbon fiber (PLA + CF), and PETG are widely employed in utensils, structural components, and biomedical device housings where load-bearing capability and chemical resistance are desirable. This is particularly relevant for reusable applications in which sterilization with hydrogen peroxide (HP) or ethylene oxide (EO) is often required. In this study, the impact of HP and EO sterilization processes on the mechanical, thermal, and structural properties of PLA, PLA + CF, and PETG was evaluated. The mechanical properties assessed included elongation at break, elastic modulus, and tensile strength after sterilization. The thermal properties examined comprised thermal stability and the coefficient of thermal expansion (CTE). Additionally, Fourier Transform Infrared Spectroscopy (FTIR) was performed to detect potential alterations in functional groups. For PLA, sterilization with HP and EO resulted in a 22% increase in ultimate tensile strength (UTS) and a 21% increase in elastic modulus, accompanied by a noticeable reduction in ductility and the appearance of more brittle fracture surfaces. PLA + CF exhibited greater stability under both sterilization methods due to the reinforcing effect of carbon fibers. In the case of PETG, tensile strength and stiffness remained stable; however, HP sterilization led to a remarkable increase in elongation at break (294%), whereas EO sterilization reduced it. Regarding thermal properties, glass transition temperature (Tg) showed variations: PLA presented either an increase or decrease in Tg depending on the sterilization treatment, PLA + CF displayed a Tg reduction after EO sterilization, while PETG exhibited a moderate Tg increase under HP sterilization. CTE decreased at lower temperatures but increased after EO treatment. FTIR analysis revealed only minor chemical modifications induced by sterilization. Overall, HP and EO sterilization can be safely applied to additively manufactured medical components based on these polymers, provided that the structures are not subjected to high mechanical loads and do not require strict dimensional tolerances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D-Printed PLA/PETG Sterilizable Static/Dynamic Modular External Finger Fracture Fixator.Bioengineering (Basel, Switzerland) · 2026
- Effect of Carbon Fiber, Graphene Nanoplatelet, and Chain‐Extender Reinforcement on the Hygrothermal Durability of 3D ‐Printed PLA Composites: A Combined Mechanical and Thermal StudyPolymer Composites · 2026
- Mechanical Parameters and Microstructural Evolution of FDM-Printed PLA and PLA+CF Under Variable Infill Architecture and Lubricant ExposurePolymers · 2025
- Enhanced PLA/PEG filaments for sustainable high-performance 3D printing using PLA synthesized from commercial lactic acidJournal of Materials Science · 2025
- Effect of thermal treatment on the mechanical behaviour of 3D-Printed carbon fiber-reinforced PLA bioplasticJournal of Elastomers & Plastics · 2026
- Fracture Behavior of Natural Fiber‐Reinforced PLA/TPU Hybrid Composites Produced by Material Extrusion Additive ManufacturingFatigue & Fracture of Engineering Materials & Structures · 2026