Technological and Physical Evaluation of a Radioprotective Marketed Cream to Assess Preformulation Studies for a Development of a Hospital Galenic Formulation
Maria Rosaria Lauro, Fausto Acernese, Patrizia Picerno, Rita Patrizia Aquino, Pierluigi D’Andria, Immacolata Pilotti, Rocco Romano
Key points
From the paper's conclusion- Therefore, characterization studies of marketed cream and preformulation studies of a preliminary binary mixtures are conducted.
Abstract
Background: Multidisciplinary healthcare teams involved in radiological procedures are continuously exposed to ionizing radiation, particularly to the hands. Medical devices such as hand gloves and UltrabloXTM, an FDA-approved hands X-ray attenuating cream, may provide some protection. Unfortunately, leaded gloves can release lead through sweating, poising a risk of dermal absorbtion, while the marketed cream is expensive, and requires large amount to adequately cover the hands or gloves. Objectives: Our goal is the development of a low-cost galenic topical device for X-ray hand protection based on bismuth oxide. Therefore, characterization studies of marketed cream and preformulation studies of a preliminary binary mixtures are conducted. Methods: UltrabloXTM is characterized using rheological, thermal spectroscopic, and morphological analyses to identify its physicochemical properties; then, preliminary formulations containing shea butter and 70% (Bi70), 80% (Bi80), or 90% (Bi90) (w/w) of Bi2O3 are prepared and evaluated using the same analytical techniques. Results: Bi80 and Bi90 show a protection comparable or superior to that of UltrabloXTM FTIR and DSC analyses confirmed the absence of chemical interactions between bismuth oxide and the lipid matrix used, indicating excellent physicochemical compatibility and structural integrity. The influence of Bi2O3 concentration on spreadability and structural organization are highlighted by rheological and SEM analyses. The better formulation is Bi80, providing an optimal balance between shielding performance, spreadability, and handling properties. Conclusions: These results demonstrate the feasibility of producing a stable, effective, and cost-effective topical radioprotective preparation, suitable for hospital formulation and potential use in clinical radiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bi2O3 katkısınının emaye frit malzemelerinin fiziksel, yapısal ve Gama/X-Işını koruma performansı üzerindeki etkisiBalıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi · 2026
- Controlling the Risk of Photon Beam Exposure with Radiation Shielding Properties of Silicon Rubber Including Tetrabutylammonium Iodide, Tungstic Oxide and Bismuth Oxide CompositesJournal of Macromolecular Science Part B · 2026
- A Nano-Bismuth-Silicone Polymer Composite as Shielding for X-Rays in Extreme-Environment Applications: Experimental and Simulation Studies.Nanomaterials (Basel, Switzerland) · 2026
- A Computational Study for Mitigating the Risk of X-Ray Exposure with Radiation Shielding Properties of Polyvinyl Chloride/Polyethylene Glycol Polymer Composites Including Bismuth Oxide, Copper Cobaltite Oxide, and Zinc Tungstate CompositesJournal of Macromolecular Science Part B · 2025
- Gamma-ray shielding performance of polystyrene composites reinforced with cadmium and bismuth oxidesThe European Physical Journal Plus · 2026
- Environmental and Non‐Toxic New Radiation Shielding Materials Alternative to Lead: Preparation, Evaluation of Their Effectiveness on Gamma Attenuation Coefficients, and Investigation of Thermal PropertiesPolymers for Advanced Technologies · 2026