The European Physical Journal Plus

Gamma-ray shielding performance of polystyrene composites reinforced with cadmium and bismuth oxides

Yasmine Abdalbasit, Sultan J. Alsufyani, Walaa M. R. Alahmade, Zinab S. Matar, Khaled Ali

Computational

Key points

From the paper's conclusion
  • These findings establish polystyrene–bismuth oxide composites as a promising, lead-free alternative for next-generation radiation shielding in weight-sensitive and environmentally conscious applications.

Abstract

The development of lightweight, non-toxic, and flexible radiation shielding materials is critical for modern medical, aerospace, and industrial applications where conventional lead and concrete shields are impractical. In this study, polystyrene-based composites reinforced with cadmium oxide and bismuth oxide at weight fractions ranging from 5 to 25 wt% were fabricated via a solution casting technique. The macroscopic structural integrity of the composites was confirmed through bulk density measurements, indicating the absence of large-scale voids and ensuring the physical suitability of the samples for subsequent attenuation experiments. Gamma-ray attenuation measurements were conducted experimentally using a narrow-beam geometry and a sodium iodide doped with thallium scintillation detector across the energy range of 0.511–1.765 MeV. The experimental results were validated against theoretical calculations using the XCOM database, showing excellent agreement with relative deviations predominantly below 5%. The linear attenuation coefficient increased systematically with filler concentration, with bismuth oxide consistently outperforming cadmium oxide due to its higher atomic number of 83 versus 48, which enhances photoelectric absorption in the low-to-intermediate energy regime. At 0.662 MeV, the 25 wt% bismuth oxide/polystyrene composite achieved a linear attenuation coefficient value of 0.1239 cm⁻ 1 , representing an 11.7% enhancement over the 25 wt% cadmium oxide/polystyrene composite. This highest concentration formulation demonstrated a half-value layer of 5.60 cm and a shielding efficiency of 11.65% at a fixed thickness of 1 cm at 0.662 MeV, marking a 26.7% reduction in required thickness and a 34% improvement in efficiency compared to pure polystyrene. Benchmarking against conventional materials revealed that the 25 wt% bismuth oxide/polystyrene composite has an areal density of 7.62 g/cm 2 , making it 11.0% lighter than ordinary concrete while approaching the weight efficiency of lead, alongside offering superior flexibility and significantly lower toxicity compared to conventional lead and cadmium-based alternatives. These findings establish polystyrene–bismuth oxide composites as a promising, lead-free alternative for next-generation radiation shielding in weight-sensitive and environmentally conscious applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers