In Silico Investigation of Electrically Guided Drug Transport Toward Morphology-Specific Brain Tumor Treatment.
Sangwoo Lee, Kyeonggu Lee, Sangjun Lee, Jimin Park, Young Bin Choy, Chang-Hwan Im
Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea. · Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
Key points
From the paper's conclusion- Conclusions: These findings support the feasibility of iontophoretic drug delivery to human brain tumors and demonstrate that the effective electrode configuration depends on tumor morphology.
Abstract
Background/Objectives: Iontophoresis employs an applied electric field to induce electromigration, enabling the active and directional transport of drug molecules. This study presents the first computational investigation of iontophoretic drug delivery targeting human brain tumors. The objective was to evaluate the feasibility of this approach and to determine how electrode configurations influence drug transport across different tumor morphologies. Methods: A realistic finite element head model was constructed from T1-weighted magnetic resonance imaging data. Two representative glioblastoma morphologies were considered: a spherical tumor in the left hemisphere and a butterfly-shaped tumor extending across the corpus callosum. Six electrode configurations spanning three categories (scalp electrodes, combined catheter and scalp electrodes, and catheter electrodes) were systematically evaluated. The electric field distribution was computed by solving the quasi-static Laplace equation, and the spatiotemporal distribution of gadobutrol was obtained using the Nernst-Planck equation. Drug delivery performance was quantified in terms of tumor coverage and targeting efficiency. Results: Under the simulated conditions, iontophoresis markedly enhanced drug delivery compared with passive diffusion, increasing tumor volume coverage from 13% to 84% in the spherical tumor model. Scalp electrode configurations resulted in the lowest tumor coverage in both tumor models. The combined catheter-scalp configuration generated radial drug transport from the catheter and achieved the highest coverage in the spherical tumor. In the butterfly-shaped tumor model, a three-catheter configuration enabled bilateral delivery along the tumor axis, achieving a tumor coverage of 49% and a targeting efficiency of 82%. The maximum electric field magnitude across all configurations was 49.26 V/m, remaining below reported axonal activation thresholds for deep brain stimulation. Conclusions: These findings support the feasibility of iontophoretic drug delivery to human brain tumors and demonstrate that the effective electrode configuration depends on tumor morphology. This study provides a computational foundation for morphology-specific planning of iontophoretic drug delivery to brain tumors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CNSC-79 Intracranial electrical fields for the treatment of glioblastomaNeuro-Oncology · 2026
- Advancing Electromagnetic Field Applications in Tumor Treating Fields TherapyITM Web of Conferences · 2026
- DDEL-10 Multifunctional, Scalable sEEG-based Platform for Targeted Drug Delivery and Neural Recording Applicable to Brain TumorsNeuro-Oncology · 2026
- Patient-Specific Electric Field Simulation In Spinal Metastasis Electrochemotherapy.Journal of visualized experiments : JoVE · 2026
- EXTH-88 Non-contact, rapidly delivered, ultra-low intensity electric field synergize with radiotherapy in glioblastomaNeuro-Oncology · 2026
- A Theoretical Framework for Ligand-Functionalised Magnetic Lipid Nanoparticles in Glioblastoma TherapyCancers · 2025