EXTH-88 Non-contact, rapidly delivered, ultra-low intensity electric field synergize with radiotherapy in glioblastoma
Paulo Roberto Del Valle, Jorge Vega, Dazhi Wang, Ayush Rana, Vijay S Thakur, Junwei Shi, John Chetley Ford, Scott Welford
Key points
From the paper's conclusion- Here we develop a capacitor system that provides a non-contact, rapidly delivered, ultra-low-intensity EF as an adjuvant to radiotherapy (RT).
Abstract
Glioblastoma (GBM) is the most common and aggressive brain cancer, with median overall survival of 14–18 months. There are efforts for therapeutic use of electric fields (EF), but the major limitation for efficacy is the subpar compliance in using a contact dependent device for a prolonged period. Here we develop a capacitor system that provides a non-contact, rapidly delivered, ultra-low-intensity EF as an adjuvant to radiotherapy (RT). The device operates at 200 kHz and 100 Vrms, generating an estimated intracranial EF of approximately 10⁻³ Vrms/cm. EF was administered for 15 min, with RT delivered at the final 5min, for 5 consecutive days. Orthotopic GBM tumors were implanted using GL261 syngeneic and 0913 human xenograft cell lines. Spontaneous genetically engineered model was generated by PTEN, P53, and NF1 knockout in intrauterine embryonic brains. No effects were observed with EF alone, however EF+RT significantly improved survival in all models. Compared with RT+temozolomide (TMZ), EF+RT+TMZ extended survival by 11 days in GL261 tumors and by more than 50 days in the 0913 model. Spontaneous tumors did not respond to RT+TMZ but adding EF increased survival by 10 days. For subcutaneous SB28 (GBM) and H460 lung carcinoma models, EF+RT significantly reduced tumor growth relative to RT alone. This effect is dose dependent on the EF input voltage. EF+RT increased γH2AX foci count at 48h and 72h after a single exposure, indicating radiation-induced DNA damage. However, clonogenic assays showed no in vitro radiosensitivity, suggesting microenvironmental contributions. Ultrasound using microbubbles as contrast agent demonstrated increased tumor perfusion after 15 minutes of EF exposure. Ongoing studies are evaluating hypoxia and oxygenation as well testing of a human-scale device. These findings indicate that low-intensity EF may enhance RT response across tumor models and support advance for clinical evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CNSC-79 Intracranial electrical fields for the treatment of glioblastomaNeuro-Oncology · 2026
- DNAR-03 Assessment of Tumor Treating Fields (TTFields) and Radiation Therapy Treatment Sequencing in Glioblastoma Preclinical ModelsNeuro-Oncology · 2026
- EP09.16 Preclinical Assessment of treatment scheduling for Tumor Treating Fields (TTFields) Applied Concurrently with Radiation Therapy in GlioblastomaNeuro-Oncology · 2026
- EXTH-54 FLASH radiation reprograms tumor associated myeloid cells and spares circulating antigen-reactive CD8+ T-cells in mouse glioblastomaNeuro-Oncology · 2026
- Magnetically actuated nanoantennas for wireless glioblastoma therapy.Science advances · 2026
- Combinatorial treatment of glioblastoma with temozolomide (TMZ) plus 5-ethynyl-2′-deoxyuridine (EdU)Proceedings of the National Academy of Sciences · 2025