Nebulized Aerosol Characteristics During Nasal High-Flow: Effect of Flow, Formulation and Impactor Temperature.
Sasi Bhushan Yarragudi, Christina Koshy Vallipurayidathil, Andrew R Martin, Stanislav Tatkov
Fisher & Paykel Healthcare Ltd., Auckland 2013, New Zealand. · Mechanical Engineering and Biomedical Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
Key points
From the paper's conclusion- Conclusions: Aerosol characteristics during NHF are governed by interacting effects of flow, formulation, and NGI/system temperature.
Abstract
Background: Aerosol delivery during nasal high-flow (NHF) therapy occurs within a heated and humidified environment where formulation composition, NHF rate, and Next Generation Impactor (NGI)/system temperature may jointly influence aerosol behavior. However, their combined effects following NHF-conditioned transport remain incompletely characterized. Methods: A balanced 4 × 2 × 2 full-factorial design evaluated NGI/system temperature (5, 21, 37, and 40 °C), formulation (isotonic and 3% hypertonic salbutamol formulations), and NHF rate (30 and 50 L·min-1). Aerosols generated using a vibrating mesh nebulizer integrated within an NHF system were transported through an adult nasal replica coupled to an NGI. Particle-size, fine-particle, delivery-efficiency, and regional-deposition metrics were analyzed using factorial ANOVA. Results: NHF rate exerted the greatest influence on downstream aerosol delivery, with increasing NHF rate reducing delivery efficiency, Fine Particle Dose (FPD), and NGI deposition while increasing NHF circuit retention. Significant Temperature × Formulation × Flow interactions were observed for MMAD (p = 0.0055), D16 (p < 0.0001), GSD (p = 0.0009), Fine Particle Fraction (FPF) (p = 0.0042), and dose-normalized FPD (p = 0.0149). The hypertonic formulation exhibited greater thermal sensitivity across several particle metrics. Although increasing NGI/system temperature generally reduced MMAD, D16, and D84, similar reductions in MMAD frequently produced markedly different responses in FPF, FPD, delivery efficiency, and regional deposition. All aerosols remained within ranges commonly associated with pulmonary deposition. Conclusions: Aerosol characteristics during NHF are governed by interacting effects of flow, formulation, and NGI/system temperature. Measurements conducted at NGI/system temperatures approaching body temperature provide additional mechanistic insight, particularly for hypertonic aerosols, and support integrated assessment of particle-size, delivery, and deposition outcomes rather than APSD metrics alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Relationship Between Flow and Absolute Humidity During Active Humidification for High-Flow Therapy: A Bench Study.Medical sciences (Basel, Switzerland) · 2026
- The Effect of Independent Humidity Control on Aerosol Drug Delivery During Adult Invasive Mechanical VentilationRespiratory Care · 2026
- Vibrating mesh nebuliser positioning during helmet CPAP: A thermo-hygrometric bench-top study.Intensive & critical care nursing · 2026
- Drug Delivery via Vibrating Mesh Nebulizer With Symmetrical and Asymmetrical High Flow Nasal Cannulas in an Adult Model.Respiratory care · 2026
- Nasal High‐Flow Therapy for Infants With Bronchiolitis Across Australia and New Zealand: A PREDICT and CIRCAN Clinician SurveyJournal of Paediatrics and Child Health · 2025
- Validating complete-airway computational fluid dynamics (CA-CFD) predictions of regional aerosol deposition in human subjects: comparisons with in vivo data of pharmaceutical aerosol delivery during HFNC therapy.International journal of pharmaceutics · 2026