Environment-Dependent UV Response of Cyclosporin A in Buffered Aqueous Media: Implications for Reliable Quantitative Analysis in Ophthalmic Drug-Delivery Research.
Iwona Nowak, Ola Michałkiewicz, Iwona Rykowska, Rafał Nowak
Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland. · Department of Ophthalmology, Józef Struś City Hospital, Szwajcarska 3, 61-285 Poznań, Poland.
Key points
From the paper's conclusion- Conclusions: These findings demonstrate that the analytical UV response of cyclosporin A is environment-dependent and highlight the importance of matrix-matched calibration and validation under the intended analytical conditions when UV spectroscopy is used for quantitative determination of CyA in aqueous drug-delivery systems.
Abstract
Background: Cyclosporin A (CyA) is widely investigated for ophthalmic drug-delivery systems, including hydrogel contact lenses, where reliable quantification is essential for evaluating drug loading, release, and formulation performance. However, the analytical UV response of CyA may depend on the physicochemical characteristics of the surrounding buffered environment, potentially affecting quantitative measurements. Objectives: This study aimed to determine whether changes in the buffered aqueous environment influence the UV spectral response of CyA and whether such variability may introduce systematic bias into UV-based quantitative analysis. Methods: UV spectra of CyA were recorded in citrate-phosphate buffered media over the pH range 3.28-9.10, including several near-neutral conditions relevant to ophthalmic formulations and artificial lacrimal media. Spectral changes were evaluated using univariate statistical analysis, principal component analysis (PCA), and Gaussian deconvolution. Results: CyA exhibited a progressive hypsochromic shift of the apparent absorption maximum from approximately 234 nm to 210-214 nm, accompanied by pronounced changes in absorbance intensity and the overall absorption profile. Comprehensive statistical analyses demonstrated systematic spectral differences across the investigated buffered media. PCA performed on 42 spectra (31 wavelength variables) explained 84.20% of the total variance within the first two principal components, while Gaussian deconvolution indicated progressive redistribution of overlapping spectral contributions. The observed spectral behavior is consistent with changes in the molecular environment and redistribution of conformational populations; however, the UV-Vis data alone do not provide direct structural evidence for these processes. The resulting wavelength-dependent spectral variability produced substantial apparent analytical bias, demonstrating that fixed-wavelength UV measurements may lead to systematic quantification errors when calibration standards and analytical samples differ in their buffered environment. Conclusions: These findings demonstrate that the analytical UV response of cyclosporin A is environment-dependent and highlight the importance of matrix-matched calibration and validation under the intended analytical conditions when UV spectroscopy is used for quantitative determination of CyA in aqueous drug-delivery systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dynamic UV-Vis monitoring of ternary pharmaceutical photodegradation using multivariate curve resolution and predictive modeling.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- DESIGN OF A PORTABLE COLORIMETRIC SYSTEM BASED ON THE COLOR SENSOR TCS3200 (GY-31) FOR DETECTING THE CONCENTRATION OF METHYLENE BLUE IN SOLUTIONSIndonesian Physical Review · 2026
- Alcian Blue-based quantification of soluble extracellular polymeric substances in microalgal and cyanobacterial cultures: optimisation, validation, and matrix-effect assessment.Methods (San Diego, Calif.) · 2026
- Topical Cyclosporine in Ophthalmology: Current Formulations, Clinical Applications, Advantages, and Limitations.Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics · 2026
- Spectroscopic Evaluation of Chemical and Physical Stability in CosmeticsCosmetics · 2026
- Water-Free Cyclosporine 0.1% in Dry Eye Disease: Formulation Rationale, Clinical Evidence, and Unresolved Questions.Drug design, development and therapy · 2026